Preview

Izmeritel`naya Tekhnika

Advanced search
Open Access Open Access  Restricted Access Subscription Access

Спектрорадиометрия ультрафиолетового излучения

Abstract

The principles of construction of primary standard detectors and sources of UV-radiation are considered. As the primary standard radiation detectors the double ionization chamber, proportional counter and cryogenic radiometer with electrical displacement are used. Spectral the characteristics of primary standard synchrotron radiation source are described by J. Schwinger theory. The results of international key comparisons confirm the high precision of methods and equipment, developed in VNIIOFI.

About the Authors

С. Аневский
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


Ю. Золотаревский
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


В. Иванов
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


В. Крутиков
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


О. Минаева
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


Р. Минаев
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


References

1. Scholze F., Beckhoff B., Brandt G., Fliegauf R., Klein R., Meyer B., Rost D., Schmitz D., Veldkamp M., Weser J., Ulm G., Louis E., Yakshin A., Oestreich S., Bijkerk F. The new PTB-beamlines for high-accuracy EUV reflectometry at BESSY II // Proc. SPIE. 2000. V. 4146. P. 72-82.

2. Scholze F., Beckhoff B., Brandt G., Fliegauf R., Gottwald A., Klein R., Meyer B., Schwarz U.D., Thornagel R., Vogel K., Weser J., Ulm G. High-accuracy EUV metrology of PTB using synchrotron radiation // Proc. SPIE. 2001. V. 4344. P. 402-413.

3. Rabus H., Persch V, Ulm G. Synchrotron-radiation operated cryogenic electrical-substitution radiometer as high-accuracy primary detector standard in the ultraviolet, vacuum ultraviolet, and soft-x-ray spectral ranges // Appl. Opt. 1997. N 36. P. 5421-5440.

4. Scholze F., Tümmler J., Ulm G. High-accuracy radiometry in the EUV range at the PTB soft x-ray radiometry beam-line // Metrologia. 2003. N 40. P. S224-S228.

5. Richter M., Johannsen U, Kuschnerus P., Kroth U., Rabus H., Ulm G., Werner L. The PTB high-accuracy spectral responsivity scale in the ultraviolet // Metrologia. 2000. N 37. P. 515-518.

6. Shaw P. S., Gupta R., Germer T.A., Arp U., Lucatorto T., Lykke K. R. Characterization of UV detectors at SURF III // Rev. Sci. Instrum. 2002. N 73. P. 1625-1628.

7. Аневский С. И., Золотаревский Ю. М., Иванов В. С., Крутиков В. Н., Минаева О. А., Минаев Р. В., Сенин Д. С. Использование синхротронного излучения для диагностики наноструктур методами УФ-спектрорадиометрии // Rusnanotech: 2-й междунар. форум по нанотехнологиям. М, 2009. С. 38-39.

8. Arp U., Friedman R., Furst M. L., Makar S., Shaw P. S. SURF III - an improved storage ring for radiometry // Metrologia. 2000. N 37. P. 357-360.

9. Anevsky S., Ivanov V., Kuznetsov V., Minaeva O., Morozov O., Pavlovitch M., Sapritsky V., Zolotarevsky Y., Vernyi A. Primary UV-radiation detector standards // Metrologia. 2003. V. 40. P. S25-S29.


Review

For citations:


 ,  ,  ,  ,  ,   . Izmeritel`naya Tekhnika. 2015;(11):26-30. (In Russ.)

Views: 85


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)