No 3 (2015)

ГОСУДАРСТВЕННЫЕ ЭТАЛОГЫ

3-6 69
Abstract
The results of developing a new secondary standard for low absolute pressures are considered. The new standard includes the best modern vacuum meters from national and foreign manufacturers. The system for of pressure maintenance was created using the modern technologies for measuring chamber manufacture. The new secondary standard meets all international requirements for metrological and technical characteristics.

GENERAL PROBLEMS OF METROLOGY AND MEASUREMENT TECHNIQUES

6-11 75
Abstract
The proposed scheme correct analysis of the measurement results in the concept of acceptable risk. For example, measurement accuracy characteristics is automatic landing, compares the three main methods of estimating the probability of finding ismere my performance in the admission, if the use of different scales of change-rhenium, namely non-parametric and parametric tolerance interval and separate confirmation requirements for Mathematica-based expectation and variance. Provides guidance on the scope and the necessary volume measurements, which should be carried out to limit the risk of violation of the established requirements acceptable level.

MEASUREMENTS IN INFORMATION TECHNOLOGIES

11-15 105
Abstract
It is shown that the main disadvantage of the Prony method at the single-frame compression-restoration of signals is the complexity of algorithm real time realization due to the labour content of calculations. The approach to compression-restoration of signals based on the combination of Prony method and decomposition on the sign-variable components is considered.

LINEAR AND ANGULAR MEASUREMENTS

15-18 92
Abstract
A method of 3D reconstruction by stereo scanning electron microscope images for calculation of the surface profile of two samples comprising trapezoidal protrusions in single-crystal silicon was applied. It is shown that the average value of the protrusions height calculated by 3D reconstruction differs from atomic force microscope (AFM) results by 2.3 % for the first sample. For the second sample additionally treated by plasma magnitudes of the protrusions obtained by both methods differ by the value less than AFM error. Better accuracy of 3D reconstruction for second sample can be explained by formation of nanometer-sized features on its surface as a result of plasma treatment improving the precision of image superposition during the 3D reconstruction.
18-23 95
Abstract
A procedure for optimizing the parameters of measuring the complex-form surfaces at contact measurement method ensuring the measurement accuracy for series of one type components is suggested. The results of procedure application for cross-sections and surfaces of gas-turbine engine compressor blades are presented.
23-25 72
Abstract
A method for estimating the components of linear dimensions of object measurement error in automated systems of computer microscopy using the object-micrometer and automated image processing - has been suggested.
26-28 73
Abstract
The basic accuracy parameters of new method for measurement of object displacements during of scanning of object image in regard to the element of multielement radiation receiver have been considered.
29-30 64
Abstract
The inductive analog-digital time type linear displacements converter has been developed. The functional circuit of the converter and its mathematical description are presented. The conversion stage is missed and the relocation is directly converted into time interval and then to digital code.

OPTICOPHYSICAL MEASUREMENTS

31-34 76
Abstract
The use of synchrotron radiation source as a primary standard source with a wide tuning range of energy and the number of accelerated electrons opens up the new opportunities for development of fundamental and applied spectroradiometry. The spectral irradiance of radiation sources comparison results by means of this source became a basis for developing the method of effective temperature determination of heat radiation. The comparator with double monochromator and cooled CCD-matrix allowing to registrate the signals with high accuracy over a wide dynamic range during determination of effective temperature dependence on source current is described.
34-38 84
Abstract
The accuracy parameters of various laser beam parallel transfer devices based on pentaprizms has been considered. The structure of error of this device has been studies. The mathematical model of the device allowing to determine the accuracy requirements for the pentaprizms initial installation and the error compensating algorithm for parallel transfer by means of initial adjustment of the system have been suggested.
39-40 140
Abstract
The measurements of radiation spectra in the waves range 380-760 nm of Hg-He lamp used for calibration of spectral instruments wavelength scale have been carried out. The time dependence of this lamp radiation lines intensity has been studied.
41-45 77
Abstract
The article contains the description of the developed test-objects and of the methodical software for measuring the spatial resolution of aerospace imaging in VNIR range. The results of experimental approbation of measurement procedure and the prospects of further use of complex testing area of MIIGAiK for validation of spectrometric characteristics of space remote sensing of Earth are considered.
45-48 80
Abstract
The modification of the known method of calibration of sun photometers at different optical air masses is suggested. The analytical condition for providing the stable periodic calibration of sun photometers taking into account the random temporal variation of atmospheric aerosol is derived. The example for realization of fuzzy calibration of sun photometer is shown.

MECHANICAL MEASUREMENTS

48-51 78
Abstract
The compact nuclear-magnetic label flowmeter is described. The basis elements of flowmeter construction and the NMR signal registration scheme have been modernized. A compact scheme of liquid flow information processing based on microcontroller has been developed. Due to the new construction of vessel-analyzer and the use of parametric resonance effect a high accuracy of measurements of liquid flow in changing range is assured.

THERMOPHYSIC MEASUREMENTS

52-55 99
Abstract
One of the most dangerous errors of thermocouples is the error caused by thermoelectric inhomogeneity acquired during long term operation of thermoelectrodes. The properties of that error the known methods of conversion characteristic drift correction are considered. The improved to decrease the impact on temperature measurements results are proposed.

ELECTROMAGNETIC MEASUREMENTS

55-57 76
Abstract
A simplified algorithm of nonlinear funning of compensator magnetic noise created by aircraft carrier and influencing the scalar magnetometer - has been studied. It is shown that the solution for this nonlinear problem can be reduced to a linear at taking into account and direct compensation of nonlinear component in the compensator equation.
58-60 104
Abstract
The effective natural-model method of definition of the normal magnetization curve and of the hysteresis loops of ferromagnetic materials in devices with the opened magnetic circuit is suggested. It is not required high computational power.
60-63 70
Abstract
Theoretically and experimentally the effect of adsorbed gas layer at the solid-liquid interface on the results of measurement of propagation velocity of longitudinal ultrasonic waves in the samples by immersion method has been studies. By means of comparison with a non-contact measuring method data the systematic component of the immersion method error was revealed.

MEDICAL AND BIOLOGICAL MEASUREMENTS

63-65 65
Abstract
The procedure of bioelectrical impedance parameters estimation based on the transient function data is considered. The analysis of errors is carried out for determination of testing pulse optimum parameters such as the front and the duration. At the same time the key role is played by the biological tissue time constant represented by Cole model. As a result of studies the functional relationships between the error of bioelectric impedance estimation and the parameters of testing pulse were obtained.

PHYSICOCHEMICAL MEASUREMENTS

65-67 80
Abstract
The calibration of the water vapor radiometer based on the joint quasi simultaneous measurements of water vapor in the atmosphere by observations of atmospheric radiation and.
68-72 57
Abstract
The hardware and software complex for control of the content of aerosolic and gaseous impurities in the ground atmosphere, its meteorological and turbulent characteristics is presented. The composition and functional scheme of complex, structure of software for the systematization and data processing of automated air quality monitoring system are considered. This complex allows to carry out the monitoring of the atmospheric impurities content at stationary point, at the routing and flare measurements.