Preview

Izmeritel`naya Tekhnika

Advanced search

Об одном подходе к оцениванию результатов ключевых сличений эталонов при несогласованных данных

About the Authors

А. Чуновкина
Всероссийский научно-исследовательский институт метрологии им. Д. И. Менделеева
Russian Federation


Н. Бурмистрова
Всероссийский научно-исследовательский институт метрологии им. Д. И. Менделеева
Russian Federation


Н. Звягин
Всероссийский научно-исследовательский институт метрологии им. Д. И. Менделеева
Russian Federation


References

1. BIPM 1999. Mutual Recognition of National Measurement Standards and of Calibration and Measurement Certificates issued by National Metrology Institutes (MRA)

2. Cox M. G.The evaluation of key comparison data //Metrologia.2002. V. 39.P. 589–595.

3. CIPM MRA-D-05 Measurement comparisons in the CIPM MRA [офиц.сайт]. www.bipm.org(датаобращения: 28.11.2012).

4. ISO/IEC Guide 99:2007International vocabulary of metrology – Basic and general concepts and associated terms (VIM)

5. Weise K., Wöger W.Removing model and datanon-conformity in measurement evaluation //Meas. Sci. Technol. 2000. N 11.P. 1649–1658.

6. Willink R.Statistical determination of a comparison reference value using hidden errors //Metrologia.2002. V. 39. P. 343–354

7. Нильсен Л. Идентификация и обращение с отличными от основной группы результатами измерений при ключевых сличениях// Измерительная техника. 2003. №5. C.63– ;Nielsen L.Identification and Handling of Discrepant Measurements in Key Comparisons // Measurement Techniques. 2003.V. 46.N5.P.513–522.

8. White D. R. On the analysis of measurement comparisons // Metrologia.2004.V. 41. P. 122–131.

9. Kacker R. Combining information from interlabaratory evaluations using a random effects model //Ibid.P. 132–136.

10. Sutton C. M. Analysis and linking of international measurement comparisons // Ibid.P. 272–277.

11. Cox M. G. The evaluation of key comparison data: determining the largest consistent subset // Metrologia.2007. V.44. P. 187–200.

12. Lira I.Combining inconsistent data from interlaboratory comparisons//Ibid.P. 415–421.

13. Elster C., Toman B.Analysis of key comparisons: estimating laboratories’ biases by a fixed effects model using Bayesian model averaging//Metrologia.2010. V. 47.P. 113–119.

14. Toman B., Possolo A.Laboratory effects models for interlaboratorycomparisons//Accreditation and Quality Assurance. 2009. V. 14. P. 553–563.

15. БоднарО. и др. Применение техники байесовского усреднения до модели с фиксированными эффектами и линейным трендом для анализа ключевого сличения CCM.P-K12 //В этом номере журнала.C 7-11.


Review

For citations:


 ,  ,   . Izmeritel`naya Tekhnika. 2013;(6):3-7. (In Russ.)

Views: 61


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)