Развитие методов воспроизведения и передачи единиц спектрорадиометрии с использованием синхротронного излучения

Abstract

The use of synchrotron radiation source as a primary standard source with a wide tuning range of energy and the number of accelerated electrons opens up the new opportunities for development of fundamental and applied spectroradiometry. The spectral irradiance of radiation sources comparison results by means of this source became a basis for developing the method of effective temperature determination of heat radiation. The comparator with double monochromator and cooled CCD-matrix allowing to registrate the signals with high accuracy over a wide dynamic range during determination of effective temperature dependence on source current is described.

About the Authors

С. Аневский
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


Ю. Золотаревский
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


В. Крутиков
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


О. Минаева
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


Р. Минаев
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


Д. Сенин
Всероссийский научно-исследовательский институт оптико-физических измерений
Russian Federation


References

1. Anevsky S., Krutikov V., Minaeva O., Minaev R., Senin D., Hollandt J., Taubert D. Method for the calibration of the spectral irradiance of tungsten filament transfer standard sources traceable to synchrotron radiation // Appl. Opt. 2013. V. 52. Р. 5152-5157.

2. Hollandt J., Jans W., Kühne M., Lindenlauf F., Wende B. A beam line for radiant power measurements of vacuum ultraviolet and ultraviolet sources in the wavelength range 40-400 nm // Rev. Sci. Instrum. 1992. N. 63 (1). Р. 1278-1281.

3. Hollandt J., Becker U., Paustian W., Richter M., Ulm G. New developments in the radiance calibration of deuterium lamps in the UV and VUV spectral range at the PTB // Metrologia. 2000. N. 37. P. 563-566.

4. Richter M., Hollandt J., Kroth U., Paustian W., Rabus H., Thornagel R., Ulm G. Source and detector calibration in the UV and VUV at BESSY II // Metrologia. 2003. N. 40. P. S107-S110.

5. Ojanen M., Karha P., Ikonen E. Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range // Appl. Opt. 2010. V. 40. N. 5. P. 714-721.


Review

For citations:


 ,  ,  ,  ,  ,   . Izmeritel`naya Tekhnika. 2015;(3):31-34. (In Russ.)

Views: 74


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)