Abstract

The principles of operation and composition of the facilities included in State Primary Standard GET 156-2015 and intended for realization and dissemination of the spectral regular transmittance and spectral specular reflectance and spectral diffuse reflectance in the wavelength range from 0,2 to 20,0 μm are described.

About the Authors

A. Yu. Dunaev
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


Yu. M. Zolotarevsky
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


S. P. Morozova
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


V. I. Sapritsky
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


G. S. Fidanian
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


A. A. Erikova
The All-Russian Research Institute for Optical and Physical Measurements
Russian Federation


References

1. Гуревич М. М. Цвет и его измерение. М.-Л.: Изд-во АН СССР, 1950.

2. Richmond J. C. Relation of Emittance to Other Optical Properties // J. Res. Natl. Bur. Stand. Engineering and Instrumentation. 1963. Vol. 67C. No. 3. P. 217-226.

3. Дунаев А. Ю., Золотаревский Ю. М., Морозова С. П., Саприцкий В. И., Фиданян Г. С., Ерикова А. А. Государственный первичный эталон единиц спектральных коэффициентов направленного пропускания, диффузного и зеркального отражений в диапазоне длин волн от 0,2 до 20,0 мкм ГЭТ 156-2015 // Измерительная техника. 2018. № 8. C. 7-9. DOI: 10.32446/0368-1025it.2018-8-7-9.

4. Annette Koo. Report on the consultative committee for photometry and radiometry key comparison of regular spectral transmittance 2010 (CCPR-K6.2010) // Metrologia. 2017. Vol. 54. 02001. DOI:10.1088/0026-1394/54/1A/02001.

5. W. Erb. Diffuse-directional radiance factor of reflection standards // Metrologia. 1997. No. 34. P. 431-432.

6. S. G. Kaplan, L. M. Hanssen, R. U. Datla. Testing the radiometric accuracy of Fourier transform infrared transmittance measurements // Appl. Opt. 1997. No. 36. P. 8896-8908.

7. Leonard M. Hanssen, Keith A. Snail. Integrating Spheres for Mid- and Near-infrared Reflection Spectroscopy // In book: Handbook of Vibrational Spectroscopy. John Wiley & Sons Ltd, Chichester, 2002.


Review

For citations:


Dunaev A.Yu., Zolotarevsky Yu.M., Morozova S.P., Sapritsky V.I., Fidanian G.S., Erikova A.A. Spectrophotometric facilities of Primary State Standard of spectral regular transmittance, spectral diffuse and spectral regular reflectance within the wavelength range from 0,2 to 20,0 μm GET 156-2015. Izmeritel`naya Tekhnika. 2018;(11):6-10. (In Russ.) https://doi.org/10.32446/0368-1025it.2018-11-6-10

Views: 123


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)