Preview

Izmeritel`naya Tekhnika

Advanced search
Open Access Open Access  Restricted Access Subscription Access

Методики дозиметрического контроля радиационных параметров клинических линейных ускорителей электронов

Abstract

Procedures of dosimetric control of radiation parameters of up-to-date electron accelerators for the morning and pretherapeutical inspections of irradiation plans for patients are considered. It is shown that the dynamic deviations of the radiation accelerators output fit into the international tolerance of ±2 %, and the width of the leakage peaks is less than 7mm. It is also shown that for IMRT irradiation plans 95 % percentage points of correspondence (75-100 %) between the calculated and measured data using gamma-method.

About the Authors

И. Лебеденко
Национальный исследовательский ядерный университет
Russian Federation


Т. Крылова
Российский онкологический научный центр им. Н. Н. Блохина МЗ РФ
Russian Federation


С. Хромов
Российский онкологический научный центр им. Н. Н. Блохина МЗ РФ
Russian Federation


Д. Неудахин
Российский онкологический научный центр им. Н. Н. Блохина МЗ РФ
Russian Federation


М. Журов
Российский онкологический научный центр им. Н. Н. Блохина МЗ РФ
Russian Federation


References

1. International Commission on Radiation Units and Measurements: ICRU 62: Prescribing, Recording and Reporting Photon Beam Therapy // Supplement to ICRU Report 50. 1999. No. 1. P. 1-8.

2. ААРМ TG-53. Гарантия качества планирования лучевого лечения. Перевод с английского // Медицинская физика. 2001. №4 (12). С. 7-24.

3. Declich F., Fumasoni К., Mangili Р. Dosimetric evaluation of a commercial 3D treatment planning system using // Report AAPM Task Group 23. Radiotherapy Onсol. 1999. No. 52. Р. 69-77.

4. Mijnheer B., Olszewska A., Fiorino C., Hartmann G., Knoos T., Rosenwald J. C., Welleweerd H. Quality assurance of treatment planning systems, Practical examples for non-IMRT photon beams // ESTRO booklet. 2004. No. 7. P. 106.

5. Comprehensive QA for radiation oncology: Report AAPM Task Group 40 // Medical Physics. 1994. V. 21. P. 581-618.

6. Code of practice for accelerators: Report AAPM Task Group 45 // Medical Physics. 1994. V. 21. P. 1093-1121.

7. Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water // International Atomic Energy Agency. 2000. No. 398. P. 1-229.

8. Prescribing, recording, and reporting intensity-modulated photon-beam therapy (IMRT) // Journal of the ICRU. 2010. V. 10. No. 1. P. 1-106.

9. Alber M., Broggi S., De Wagner C. Eichwurzel I., Engstrom P., Fiorino C., Georg D., Hartmann G., Knoos T., Leal F., Martijnissen., Mijnheer B., Paiusco M., Sanchez-Doblado F., Schmidt R., Tomsej M., Welleweerd H. Guidelines for the verification of IMRT // ESTRO booklet. 2008. No. 9. P. 150.

10. Ezzel G. A., Burmeister J. W., Dogan N. IMRT commissioning: multiple institution planning and dosimetry comparisons. Report AAPM Task Group 119 // Medical Physics. 2009. V. 36. No. 11. P. 5359-5373.

11. Klein E. E., Hanley J., Bayouth J. Quality Assurance of Medical Accelerations. AAPM Task Group 142 Report // Medical Physics. 2009. V. 36. No. 9. Р. 4197-4212.

12. Казанцев П. В., Лебеденко И. М., Крылова Т. А., Прусова М. П., Журов Ю. В., Климанов В. А. Практическое применение устройства портальной дозиметрии для проведения ежедневных проверок в рамках программы гарантии качества ускорителей электронов // Медицинская техника. 2016. № 1. С. 52-55.

13. Лебеденко И. М., Шатенок М. П., Крылова Т. А., Журов Ю. В., Казанцев П. В. Рационализация режима проведения предтерапевтических проверок планов ЛТМИ // Медицинская физика. 2015. № 1 (65). С. 45-52.


Review

For citations:


 ,  ,  ,  ,   . Izmeritel`naya Tekhnika. 2017;(4):53-56. (In Russ.)