Extreme accuracy of the autocollimator-null-indicator
https://doi.org/10.32446/0368-1025it.2025-2-64-69
Abstract
Improving the accuracy of measurements in dynamic goniometry is inextricably linked with achieving the ultimate accuracy of the optical null indicator. This device is part of angle measuring devices operating on the principle of a dynamic goniometer. The autocollimator-null-indicator, when its optical axis coincides with the normal to the controlled reflecting surface, generates an electric pulse, which is used to read the readings of the angular scale of the dynamic goniometer. The ultimate accuracy of the autocollimator-null-indicator is determined by its random error. The random error of measurements of the constant angular position of a reflecting mirror at different times of the day was experimentally studied. It is shown that external noises prevail during daytime measurements – various vibrations, air and external lighting fluctuations, which depend on the distance between the autocollimator-null-indicator and the mirror, and during nighttime measurements the influence of external effects on the measurement results is minimal, which made it possible to obtain the measurement error at night at the flicker noise level. The experimental data are analyzed using the methods of mathematical statistics, Allan variance and wavelet analysis. It is determined that the arrays of random variables characterizing the random error are non-stationary. The minimum value of the random error of the autocollimator-null-indicator was 0.001″.
The presented results are of interest to specialists developing and using optoelectronic devices based on the autocollimator.
About the Authors
E. M. IvashchenkoRussian Federation
Elena M. Ivashchenko
St. Petersburg
R. A. Larichev
Russian Federation
Roman A. Larichev
St. Petersburg
P. A. Pavlov
Russian Federation
Petr A. Pavlov
St. Petersburg
References
1. Burnashev M. N., Pavlov P. A., Filatov Yu. V. Development of Precision laser goniometer systems. Quantum Electronics, 43(2), 130–138 (2013). https://doi.org/10.1070/QE2013v043n02ABEH015045
2. Larichev R. A., Filatov Yu. V. A model of angle measurement using an autocollimator and optical polygon. Photonics, 10(12), 13–59 (2023). https://doi.org/10.3390/photonics10121359
3. Venediktov V. Yu., Nyamweru B., Larichev R. A. et. al. Optical null-indicators for goniometric systems: a review. Photonics, 16(6), 464–474 (2022). https://doi.org/10.22184/1993-7296.FRos.2022.16.6.464.474
4. Slaev V. A. (eds.) Potential measurement accuracy. NPO “Professional”, St. Petersburg (2005). (In Russ.)
5. Ishanin G. G., Chelibanov V. P. Optical radiation receivers. Lan’, St. Petersburg (2022). (In Russ.)
6. Yakimov A. N. Physics of noise and fluctuations of parameters. Nizhny Novgorod State University, Nizhny Novgorod (2013). (In Russ.)
7. Bendat J. S., Piersol A. G. Random Data Analysis and Measurement Procedures. John Wiley & Sons, Inc. (1986).
8. Allan D. W. Statistics of atomic frequency standards. Proceeding. IEEE, 54(2), 221–230 (1966). http://dx.doi.org/10.1109/PROC.1966.4634
9. Mary Beth Ruskai, Gregory Beylkin et al. Wavelets and their Applications, Jones and Barlett Publisher, Boston, (1992).
10. Yakovlev A. N. Introduction to wavelet transformations. NSTU Publ., Novosibirsk (2003). (In Russ.)
11. Mallat S. A wavelet tour of signal processing. Academic Press (1999).
12. Matsaev A. S. Flicker-noise. Features, diversity and management. Journal of Radio Electronics, (10), 1–17 (2020). https://doi.org/10.30898/1684-1719.2020.10.7
13. Kachanov B. O., Akhmedova S. A., Tuktarev N. A. et al. Flicker noise simulation by superposition of normal stationary process. Giroskopy and Navigation, 9(3), 218–226 (2018). https://doi.org/10.1134/S2075108718030045
14. Korolev A. N., Lukin A. Ya., Filatov Yu. V., Venediktov Yu. V. Matrix measurement technology: accuracy of measuring element coordinates and photomask control. Journal of Optical Technology, 91(3), 203–208 (2024). https://doi.org/10.1364/JOT.91.000203
Supplementary files