Inf uence of the variable geometry of the diverter nozzle on the metrological characteristics of a calibration unit with weighing devices
https://doi.org/10.32446/0368-1025it.2023-7-30-40
Abstract
This article discusses the issues of improving the metrological characteristics, weight-dimensional and technical and economic indicators of calibration installations with weighing devices due to the introduction of a fl ow switch with a variable nozzle exit geometry into their design. It is assumed that the use of this design of the fl ow switch will solve the problem of fi lling the nozzle exit with water, reduce the dimensions of the hydraulic path, simplify the maintenance procedure, and reduce the cost of installations. A description of the design, principles of operation and a timing diagram of a fl ow switch with a variable nozzle exit geometry are presented. The local hydrodynamic characteristics of the water fl ow by a Pitot tube in the nozzle exit are studied with a change in its width in the mass fl ow rate range from 25 to 550 t/h. The optimal values of the nozzle cut width are experimentally determined depending on the value of the mass fl ow rate of the liquid, at which it is completely fi lled with liquid. A study of the metrological characteristics of a calibration installation with weighing devices, which includes a fl ow switch with a variable nozzle exit geometry, methods of indirect measurements and comparisons using a comparison standard in a wide range of liquid mass fl ow rates, has been carried out. The impact on the metrological characteristics of a calibration installation with weighing devices of the nozzle cut width in the investigated range of liquid fl ow is established. Graphical dependences of the expanded measurement uncertainty of the installation when reproducing the unit of liquid mass fl ow rate on the measurement time interval and on the mass fl ow rate of the liquid are presented. Based on the research results, the optimal values of the nozzle cut width and measurement time intervals were determined depending on the mass fl ow rates of the liquid when using a fl ow switch with a variable nozzle cut geometry. The expansion of the range of operation of weighing devices, which are part of the verifi cation installations with weighing devices, is justifi ed. According to the results of the research, the proposed design of the fl ow switch with a variable geometry of the nozzle exit is recommended for use in the design of new and modernization of installations for calibration with weight devices of fl ow switches.
About the Authors
A. A. KorneevRussian Federation
Andrey A. Korneev
St. Petersburg
Kazan
A. V. Shchelchkov
Russian Federation
Alexey V. Shchelchkov
Kazan
R. A. Korneev
Russian Federation
Roman A. Korneev
Kazan
References
1. Yang W., Wang X., Chen Y., Shen Y. Jiliang Xuebao/Acta Metrologica Sinica, 2023, vol. 44, no. 4, pp. 598–603. https://doi.org/10.3969/j.issn.1000-1158.2023.04.16
2. Haiyang L., Liang Z., Bian H., Xuejing L., Yuyang C. Journal of Physics: Conference Series, 2021, vol. 1865, 042135. https://doi.org/10.1088/1742-6596/1865/4/042135
3. Jaiswal S. K., Yadav S., Bandyopadhyay A. K., Agarwal R. MAPAN – Journal of Metrology Society of India, 2012, vol. 27, no. 2, pp. 63–67. https://doi.org/10.1007/s12647-012-0017-x
4. Chun S., Yoon B.-R. 18th Int. Conf. on Nanochannels, Microchannels, and Minichannels, July 13–15, 2020, Virtual, Online, ASME, 2020, vol. 1, V001T02A013. https://doi.org/10.1115/FEDSM2020-20045
5. Shimada T., Oda S., Terao Y., Takamoto M, Flow Measurement and Instrumentation, 2003, vol. 14, pp. 89–96. https://doi.org/10.1016/S0955-5986(03)00016-5
6. Engel R., Beyer K., and Baade H.-J, Measurement Science and Technology, 2012, vol. 23, no. 7, 074020. https://doi.org/10.1088/0957-0233/23/7/074020
7. Korneev R. A., Tukhvatullin A. R., Fafurin V. A., Nigmatullin R. R., Shchelchkov A. V. Measurement Techniques, 2020, vol. 63, pp. 140–144. https://doi.org/10.1007/s11018-020-01763-7
8. Korneev R. A., Tukhvatullin A. R., Fafurin V. A., Shchelchkov A. V. Measurement Techniques, 2019, vol. 62, pp 347–353. https://doi.org/10.1007/s11018-019-01628-8
9. Korneev R. A., Tukhvatullin A. R., Fafurin V. A., Shchelchkov A. V., Ataeva A. I. Measurement Uncertainties Estimation Introduced by the Diverter Into the Budget of Standard Uncertainties, Proceedings of 18th International Flow Measurement Conference – FLOMEKO 2019, Lisbon, Portugal, 26–28 June, 2019, IMEKO, 161254.
10. Korneev A. A, Korneev A. M., Shchelchkov A. V., Kraev D. V., Patent RU 2781556 C1, Inventions. Utility models, no. 29 (2022)
11. Shchelchkov, A. V., Fafurin, V. A., Korneev, R. A., Tukhvatullin R. R. Flow Measurement and Instrumentation, 2022, 83, 102117. https://doi.org/10.1016/j.fl owmeasinst.2021.102117
12. Picard A., Davis R., Gläser M., Fujii K., Metrologia, 2008, vol. 45, pp. 149–155. https://doi.org/10.1088/0026-1394/45/2/004
13. Meng T., Wang С., Gao F, Xing C., Zhang L. Design and Experimental Analysis of Transfer Standard in Water Flow Compari son, 16th International Flow Measurement Conference, FLOMEKO 2013, Paris, 24–26 September, 2013, IMECO, 2014, Curran Associates, Inc., pp. 50–60.
14. Frahm E., Mickan B., Gulyuk V., Reut G., Zigmantas G., Benkova M., Kayumov M., Metrologia, 2020, vol. 57, no. 1A, pp. 07023. https://doi.org/10.1088/0026-1394/57/1A/07023
15. Albaina I., Esteban G. A., Bidaguren I., Izquierdo U. Flow Measurement and Instrumentation, 2023, vol. 93, 102425. https://doi.org/10.1016/j.fl owmeasinst.2023.102425
Review
For citations:
Korneev A.A., Shchelchkov A.V., Korneev R.A. Inf uence of the variable geometry of the diverter nozzle on the metrological characteristics of a calibration unit with weighing devices. Izmeritel`naya Tekhnika. 2023;(7):30-40. (In Russ.) https://doi.org/10.32446/0368-1025it.2023-7-30-40