Gas sensors for measurement of the concentration toxic substances: peculiarities of the use
https://doi.org/10.32446/0368-1025it.2021-10-65-71
Abstract
The advantages and disadvantages of the gas sensors for measurement of content of the toxic substances in a working zone are reviewed. The main standarts and normative documents setting the requirements for instrument for measuring of content of the harmful substances in a working zone air are considered. Experimental setup for research of the amperometric sensors characteristics, measurement procedure and experimental results are described. Comparative analysis of the characteristics of sensors produced by various manufacturers are presented. Recommendations are given on the practical use of the obtained date for development of the measuring instruments satisfying the requirements of the domestic regulations.
About the Authors
V. M. TelezhkoRussian Federation
Vladislav M. Telezhko
St. Petersburg
M. V. Tyutchev
Russian Federation
Mikhail V. Tyutchev
St. Petersburg
M. V. Averianova
Russian Federation
Marija V. Averianova
St. Petersburg
A. D. Paranin
Russian Federation
Alexandr D. Paranin
St. Petersburg
E. V. Khoina
Russian Federation
Evgeniy V. Khoina
St. Petersburg
References
1. Rene Knake, Patrick Jacquinot, Alexia W. E. Hodson, Peter C. Hauser, Analitica Chimica Acta, 2005, vol. 549, no. 1-2, pр. 1–9. https://doi.org/10.1016/j.aca.2005.06.007
2. Stetter J. R, Li J., Chem. Rev., 2008, vol. 108, pp. 352– 366. https://doi.org/10.1021/cr0681039
3. Gary W. Hunter, Sheikh Akbar, Shekhar Bhansali et al., Journal of The Electrochemical Society, 2020, vol. 167, 037570. https://doi.org/10.1149/1945-7111/ab729c
4. Gatty H. K., Leijonmarck S., Antelius M. et al., Sensor and Actuators B-Chemical, 2015, vol. 209, pp. 639–644. https://doi.org/10.1016/j.snb.2014.11.147
5. Zajda J., Schmidt N. J., Zheng Z. et al., Electroanalysis, 2018, vol. 30, no. 8, pp. 1602–1607. https://doi.org/10.1002/elan.201800140
6. Ronan Baron, John Saff ell, ACS Sensors, 2017, vol. 2, no. 11, pp. 1553–1566. https://doi.org/10.1021/acssensors.7b00620
7. Angela Mihaeva Baracu, Livia Alexandra Dinu Gugoasa, Journal of The Electrochemical Society, 2021, vol. 168, no. 3, 037503. https://doi.org/10.1149/1945-7111/abe8b6
8. Gebicki J., Chachulski B., Sensor and Actuators B: Chemical, 2009, vol. 141, no. 1, рp. 249–255. https://doi.org/10.1016/j.snb.2009.06.024
9. Anirban Paul, Sriram Muthukumar, Shalini Prasad, Journal of The Electrochemical Society, 2020, vol. 167, no. 3, 037511. https://doi.org/10.1149/2.0112003JES
10. Paranin A. D., Telezhko V. M., Tyutchev M. V., Khoyna E. V., Electrochemical sensor for control hydrogen cyanide concentration in air of a working zone, Sensors and Systems, 2016, no. 12, pp. 49–54. (In Russ.)
Review
For citations:
Telezhko V.M., Tyutchev M.V., Averianova M.V., Paranin A.D., Khoina E.V. Gas sensors for measurement of the concentration toxic substances: peculiarities of the use. Izmeritel`naya Tekhnika. 2021;(10):65-71. (In Russ.) https://doi.org/10.32446/0368-1025it.2021-10-65-71