The impulse pressure transducers: applicability criteria
https://doi.org/10.32446/0368-1025it.2021-10-34-40
Abstract
The problem of search and verification of criteria of sampling of the transducer of certain type depending on prospective entrance affecting - criteria of usability of the impulse (dynamic) pressure transducer, based on its dynamic characteristics is observed. Thus similar transducers are widely used at research fluid-gas-dynamics processes. Existing rules in the field of measurement of pulsing pressures are systematized. Dynamic characteristics of impulse pressure transducers of several types are experimentally investigated, their transfer functions are gained and responses of transducers to set entrance affecting are simulated. The experimental method of reception of a transfer function with use of a pneumatic shock tube and applied mathematical software packages is offered. Absence of uniform universal criterion of usability of the impulse pressure transducer depending on prospective entrance affecting is confirmed. Results of research can be claimed at a choice of necessary type of the transducer at measurement of impulse (dynamic) pressure in various tasks of a science and technics.
About the Author
A. A. NedbayloRussian Federation
Аndrey А. Nedbaylo
Snezhinsk, Chelyabinsk region
References
1. Bean V. E., Dynamic Pressure Metrology, Metrologia, 1994, vol. 30, iss. 6, pр. 737–741. https://doi.org/10.1088/0026-1394/30/6/037
2. Tomasi L., Wieser E., Baruah E., Collomb D., Jolly F., Krötz G., Storm S., Jänker P., Obermeier E., Development of a new piezoelectric dynamic pressure generator for high pressure periodic and aperiodic calibration, Proceedings of the XVII IMEKO World Congress, Dubrovnik, Croatia, June 22–27, 2003, IMEKO and HMD Publ., 2003, pр. 1995–1996.
3. Tsing T. T., Ho Ch., Chen L. Ch., Wu J. L., Han L. L., Measurement science and technology, 2003, vol. 14, pp. 1927–1337. https://doi.org/10.1088/0957-0233/14/11/010
4. Elkarous L., Coghe F., Pirlot M., Golinval J. C., J. Phys., Conf. Ser., 2013, no. 459, 012048. https://doi.org/10.1088/1742-6596/459/1/012048
5. Bruns Th., Franke E., Kobusch M., Metrologia, 2013, no. 50, pр. 580–585. https://doi.org/10.1088/0026-1394/50/6/580
6. Salminen J., Hogstrom R., Saxholm S., Lakka A., Riski K.,
7. Heinonen M., Metrologia, 2018, vol. 55, no. 2, S52–S59. https://doi.org/10.1088/1681-7575/aaa847
8. Bagdat’ev E. E., Efi mova A. A., Sanina E. B., Measurement Techniques, 1989, no. 32, pp. 212–213. https://doi.org/10.1007/BF00865299
9. Kuznetsov E. A., Measurement Techniques, 1993, no. 36, pp. 682–686. https://doi.org/10.1007/BF00980016
10. Mark Serridge, Torben R. Licht, Piezoelectric Accelerometers and Vibration Preamplifi ers: Theory and Application Handbook, Denmark, К. Larsen and Son A/S, 1987, 160 p.
11. Patrick L. Walter, Shock and Blast Measurement – Rise Time Capability of Measurement Systems?, available at: http:// www.pcb.com/contentstore/MktgContent/linkeddocuments/technotes/TN-11-0904_Calculating_Rise_Time.pdf (accessed: 05.09.2021).
12. Stryzniou A. G., Marcov A. V., Rusakovich A. N., Control object identifi cation using closed-loop system transient response, Doklady BGUIR, 2012, no. 5, pp. 65–72. (In Russ.)
13. A. G. Gaydon, I. R. Hurle, The shock tube in high-temperature chemical physics, Chapman and Hall Ltd, London, 1963, 367 p.
14. Matthews С., Pennecchi F., Eichstädt S., Malengo A., Esward T., Smith I., Elster C., Knott A., Arrhén F., Lakka A., Metrologia, 2014, vol. 51, no. 3, pp. 326–338. https://doi.org/10.1088/0026-1394/51/3/326
15. Shipunov A. V., Opredelenie dinamicheskikh kharakteristik p’ezoelektricheskikh datchikov davleniya: sravnitel’nyi analiz metodov [Determination of the dynamic characteristics of piezoelectric pressure sensors: a comparative analysis of methods], Pribory i sistemy upravleniya, 1999, no. 7, pp. 35–37. (In Russ.)
16.
Review
For citations:
Nedbaylo A.A. The impulse pressure transducers: applicability criteria. Izmeritel`naya Tekhnika. 2021;(10):34-40. (In Russ.) https://doi.org/10.32446/0368-1025it.2021-10-34-40