Preview

Izmeritel`naya Tekhnika

Advanced search
Open Access Open Access  Restricted Access Subscription Access

The uncertainty of residual life indicator measurement by thermal method for respirator cartridge

https://doi.org/10.32446/0368-1025it.2020-11-49-53

Abstract

Filtering and absorbing products in the form of a plate and working under conditions of convective blowing with cleared air residual life indicator uncertainties of measurement analysis is carried out. It is shown that for 0.8 mm thick KO2-based sorbent plates at a relative humidity of 60…90 % and a CO2 concentration of 1…4 %, the main factor of the uncertainty of indirect measurement of the residual life indicator is the Biot parameter characterizing the conditions of heat transfer from the plate surface. It has been experimentally proven that for Biot parameter in the range of 0–0.08, this factor contributes up to 30 % in the total uncertainty.

About the Authors

P. V. Balabanov
Tambov State Technical University
Russian Federation

Pavel V. Balabanov

Tambov



I. V. Ryazanov
Tambov State Technical University
Russian Federation

Ivan V. Ryazanov

Tambov



References

1. Wood G. O., Snyder J. L., Journal of occupational and environmental hygiene, 2011, no. 8 (10), pp. 609–617. https://doi.org/10.1080/15459624.2011.606536

2. Nelson T. J., Janssen L. L., 3M Jobhealth Highligts, 1999, no. 1 (17), pp. 1–5.

3. Favas J., Human protection & performance division defence science and technology organization, 2005, available at: https://fi les.library.by/files/1573381407.doc(accessed:22.04.2020).

4. Greenawald L. A., Boss G. R., Reeder A., Bell S., Sensors and Actuators B: Chemical, 2016, vol. 230, pp. 658–666. https://doi.org/10.1016/j.snb.2016.02.129

5. Gromov О. B., Dyachenko А. N., Zernaev P. V., RF Patent no. 2459204, Byull. Izobret., no. 23 (2012).

6. Mason A., Wylie S., Shaw A., Al-Shamma’a A. I., Thomas A., Keele H., Journal of Physics: Conference Series, 2011, vol. 307, no. 1, pp. 1–6. https://doi.org/10.1088/1742-6596/307/1/012041

7. Cerro G., Ferrigno L., Ferdinandi M., Laracca M., IEEE Transactions on Instrumentation and Measurement, 2018, vol. 67, no. 10, pp. 2504–2515. https://doi.org/10.1109/TIM.2018.2843218

8. Bernard P., Caron S., St. Pierre M., Lara J., US Patent no. 6375725 (23.05.2002).

9. Hajime H., Ishidao T., Ishimatsu S., Journal of occupational and environmental hygiene, 2003, vol. 18, no. 2, pp. 90–95. https://doi.org/10.1080/10473220301438

10. Kondroshov S. N., RF Patent no. 2419783, Byull. Izobret., no. 12 (2011).

11. Mishchenko S. V., Balabanov P. V., Krimshtein A. A., Theoretical foundations of chemical engineering, 2014, vol. 48, no. 3, pp. 328–336.https://doi.org/10.1134/S0040579514030130

12. Balabanov P. V., Mishchenko S. V., Measurement Techniques, 2015, vol. 57, no. 10, рр. 1219–1224. https://doi.org/10.1007/s11018-015-0606-5

13.


Review

For citations:


Balabanov P.V., Ryazanov I.V. The uncertainty of residual life indicator measurement by thermal method for respirator cartridge. Izmeritel`naya Tekhnika. 2020;(11):49-53. (In Russ.) https://doi.org/10.32446/0368-1025it.2020-11-49-53

Views: 88


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)