Supercontinuum laser-based monochromatic radiant source for detector spectral responsivity characterization in the range 0.9–1.6 μm using absolute cryogenic radiometer

https://doi.org/10.32446/0368-1025it.2020-11-28-33

Abstract

An improved monochromatic radiant source with spectral bandwidth of 4 nm based on supercontinuum laser and a double monochromator was included in absolute cryogenic radiometer-based facility to improve the accuracy of spectral responsivity measurement in the range 0.9–1.6 μm. The developed feedback system ensures stabilization of monochromatic radiant power with standard deviation up to 0.025 %. Radiant power that proceeds detector under test or absolute cryogenic radiometer varies from 0.1 to 1.5 mW in dependence of wavelength. The spectral power distribution of its monochromatic source for various operating mode is presented.

About the Authors

A. Yu. Dunaev
All-Russia Research Institute for Optical and Physical Measurements
Russian Federation

Aleksandr Yu. Dunaev

Moscow



A. S. Baturin
All-Russia Research Institute for Optical and Physical Measurements
Russian Federation

Andrey S. Baturin

Moscow



V. N. Krutikov
All-Russia Research Institute for Optical and Physical Measurements
Russian Federation

Vladimir N. Krutikov

Moscow



S. P. Morozova
All-Russia Research Institute for Optical and Physical Measurements
Russian Federation

Svetlana P. Morozova

Moscow



References

1. Sapritsky V. I., Krutikov V. N., Ivanov V. S., et al, Metrologia, 2012, vol. 49, S9–S16. https://doi.org/10.1088/0026-1394/49/2/S9

2. Metzdorf J., Winter S., and Wittchen T., Metrologia, 2000, vol. 37, pp. 573–578. https://doi.org/10.1088/0026-1394/37/5/52

3. Glasov A. I., Grigorev V. V., Ivanov V. S., Kravtsov V. E., Mityurev A. K., Tikhomirov S. V., Krutikov V. N., Photon-Express, 2015, no.8 (128), pp. 18–21 (in Russian).

4. Morozova S. P., Konovodchenko V. A., Sapritsky V. I., Lisiansky B. E., Morozov P. A., Melenevsky U. A., and Petic A. G., Metrologia, 1995/96, vol. 32, S557–S560. https://doi.org/10.1088/0026-1394/32/6/31

5. Nan Xu, Yandong Lin, Haiyong Gan, Jianwei Li, Proc. SPIE 10155, Optical Measurement Technology and Instrumentation, 1015513 (19 October 2016). https://doi.org/10.1117/12.2245666

6. Gamouras A., Todd A. D. W., Côté É., and Rowell N. L., IOP Conf. Series: Journal of Physics: Conf. Series, 972, (2018), 012014. https://doi.org/10.1088/1742-6596/972/1/012014

7. Woodward J. T., Smith A. W., Jenkins C. A., Chungsan Lin, Brown S. W., and Lykke K. R., Metrologia, 2009, vol. 46, S277–S282. https://doi.org/10.1088/0026-1394/46/4/S27

8. Levick A. P., Greenwell C. L., Ireland J., Woolliams E. R., Goodman T. M., Bialek A., and Fox N. P., Applied Optics, 2014, vol. 53, no. 16, pp. 3508–3519. https://doi.org/10.1364/AO.53.003508

9. Gavrilov V. R., Dunaev A. Y., Lisyanskii B. E. et al., Measurement Techniques, 2016, vol. 58, pp. 1200–1204. https://doi.org/10.1007/s11018-016-0869-5

10. Earle K. Plyler, Lamdin R. Blaine, and Eugene D. Tidwell, Journal of Research of the National Bureau of Standards, 1955, vol. 5, no. 5, pp. 279–284. http://dx.doi.org/10.6028/jres.055.032


Review

For citations:


Dunaev A.Yu., Baturin A.S., Krutikov V.N., Morozova S.P. Supercontinuum laser-based monochromatic radiant source for detector spectral responsivity characterization in the range 0.9–1.6 μm using absolute cryogenic radiometer. Izmeritel`naya Tekhnika. 2020;(11):28-33. (In Russ.) https://doi.org/10.32446/0368-1025it.2020-11-28-33

Views: 157


ISSN 0368-1025 (Print)
ISSN 2949-5237 (Online)