The modif ed optical part of a pyrometer used for calibrating tungsten-rhenium thermocouples
https://doi.org/10.32446/0368-1025it.2021-1-43-47
Abstract
The provision of technological processes with modern techniques for measuring temperature is a challenging issue. For solving this problem there need to be formulated specifi c requirements for the optical part of the pyrometer, intended for measuring the temperature in the measurement cavity of the installation used for calibrating tungsten-rhenium thermocouples up to a temperature of 2,200 °С. In accordance with these requirements, in mass produced “Termokont” pyrometer, its optical part has been modifi ed and experimentally investigated.
About the Authors
V. K. BityukovRussian Federation
Vladimir K. Bityukov
Moscow
R. A. Gorbunov
Russian Federation
Ruslan A. Gorbunov
Kaluga
D. S. Simachkov
Russian Federation
Denis S. Simachkov
Moscow
A. A. Ulanovsky
Russian Federation
Anatoly A. Ulanovsky
Obninsk, Kaluga Region
A. V. Frunze
Russian Federation
Alexandr V. Frunze
Moscow
References
1. Bityukov V. K., Nefedov V. I., Simachkov D. S., Rossiyskiy tekhnologicheskiy zhurnal, 2019, vol. 7 (2), pp. 5–17 (in Russian). https://doi.org/10.32362/2500-316X-2019-7-2-5-17
2. Ionov A. B., Measurement Techniques, 2013, vol. 56, no. 6, pp. 658–663. https://doi.org/10.1007/s11018-013-0262-6
3. Magunov A. N., Pribory i tekhnika eksperimenta, 2009, no. 4, рр. 5–28 (in Russian). 4. Magunov A. N., Technical Physics. The Russian Journal of Applied Physics, 2010 , vol. 55 , no. 7, pp. 991–995.
4. Rusin S. P., High Temperature, 2018, vol. 56, no. 2, pp. 193–200.
5. Levin E. V., Okunev A. Y., Measurement Techniques, 2015, vol. 58, no. 5, pp. 544–549. https://doi.org/10.1007/s11018-015-0751-x
6. Ulanovsky A. A., Maletsky R. R., Khlevnoi B. B., Otryaskin D. A., Pribory, 2019, no. 6, pp. 7–14 (in Russian).
7. Latyev L. N., Petrov V. A., Chekhovskoi V. Ya., Shestakov E. N., Radiation properties of solids. Handbook, ed. A. Ye. Sheindlin, Moscow, Energia Publ., 1974. 472 p. (in Russian).
8. Khadson R., Infrared systems, Wiley, 2006, 642 p.
9. Harrison T. R., Radiation pyrometry, New York, London, Wiley & Sons, 1960, 234 p.
10. Frunze A. V., Measurement Techniques, 2013, vol. 55, no. 10, рр. 1172–1177. https://doi.org/10.1007/s11018-012-0104-y
Review
For citations:
Bityukov V.K., Gorbunov R.A., Simachkov D.S., Ulanovsky A.A., Frunze A.V. The modif ed optical part of a pyrometer used for calibrating tungsten-rhenium thermocouples. Izmeritel`naya Tekhnika. 2021;(1):43-47. (In Russ.) https://doi.org/10.32446/0368-1025it.2021-1-43-47