Передача температуры тройной точки воды на акустический резонатор методом сравнения

Abstract

Detailed analysis of the method used to transfer the temperature value from the water triple point cell (TPW) to the acoustic resonator of the installation for measuring the Boltzmann constant is presented. The transfer of the temperature value from TPW to the resonator is performed, using a highly sensitive differential sensor which however can not be considered as the absolute measuring instrument. The method is proved to allow the transfer with the uncertainty limited only by thermal noises. The method enables to lower uncertainty of the transfer of Boltzmann constant measuring results, which is needed for redefining the Kelvin unit in terms of the Boltzmann constant.

About the Authors

В. Малышев
Всероссийский научно-исследовательский институт физико-технических и радиотехнических измерений
Russian Federation


К. Пилипенко
Всероссийский научно-исследовательский институт физико-технических и радиотехнических измерений
Russian Federation


References

1. Fischer J., Gerasimov S., Hill K. D., Machin G., Moldover M. R., Pitre L., Steur P., Stock M., Tamura O., Ugur H., White D. R., Yang I., Zhang J. Steps towards the New Definition of the Kelvin in Terms of the Boltzmann Constant // Int. J. Thermophysics. 2007. N. 28. Р. 1753-1765.

2. Report from the Miseen Pratique Task Group to the CIPM: the next international temperature scale and the miseen pratique for the definition of the kelvin New Determinations of Thermodynamic Temperature and the Boltzmann Constant // Work. Doc. 23rd Meeting of the Consultative Committee for Thermometry. BIPM. 2005.

3. Michael R. Moldover. Optimizing Acoustic Measurements of the Boltzmann Constant. // C. R. Physique. 2009. N. 10. Р.815-827.

4. Moldover M. R., Trusler P. M, Edwards T. J., Mehl J. B., Davis R. S. Measurement of the Universal Gas Constant R Using a Spherical Acoustic Resonator // J. Res. Natl. Inst. Stand. Technol. 1988. N. 93. Р. 93-173.

5. Hill1 K. D., Steele A. G., Dedikov Y. A., Shkraba V. T. NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K. 2005.

6. Pitre L., Sparasci F., Truong D., Guillou A., Risegari L., Himbert ME. Measurement of the Boltzmann Constant kB Usinga Quasi-Spherical Acoustic Resonator // Int. J. Thermophysics. 2011. N. 32. Р.1825-1886.

7. OMEGA Engineering, INC. [Электрон. ресурс] http://www.omega.com/pptst/SPIR.html (дата обращения: 20.04.2016).

8. ГОСТ Р 54500.3-2011. Руководство ИСО/МЭК 98-3:2008 Неопределенность измерения. Часть 3. Руководство по выражению неопределенности измерения.


Review

For citations:


 ,   . Izmeritel`naya Tekhnika. 2016;(11):33-36. (In Russ.)

Views: 97


ISSN 0368-1025 (Print)