<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.32446/0368-1025it.2019-3-64-67</article-id><article-id custom-type="elpub" pub-id-type="custom">izmertech-953</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МЕДИЦИНСКИЕ И БИОЛОГИЧЕСКИЕ ИЗМЕРЕНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>MEDICAL AND BIOLOGICAL MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>Помехоустойчивость методик контурного анализа пульсовой волны</article-title><trans-title-group xml:lang="en"><trans-title>Noise immunity of pulse wave contour analysis</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Федотов</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Fedotov</surname><given-names>A. A.</given-names></name></name-alternatives><email xlink:type="simple">fedoaleks@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Самарский национальный исследовательский университет им. акад. С. П. Королева</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Samara National Research University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>3</issue><fpage>64</fpage><lpage>67</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/953">https://www.izmt.ru/jour/article/view/953</self-uri><abstract><p>Проанализирована помехоустойчивость методик контурного анализа пульсовой волны. Рассмотрены различные подходы к реализации контурного анализа пульсовой волны. Показано, что классические подходы морфологического анализа пульсовой волны на основе использования индексов жёсткости и отражения не обеспечивают достаточной диагностической точности в силу неустойчивого обнаружения максимума отражённой волны. Предложена методика контурного анализа на основе спектральных преобразований последовательности реплицированных фрагментов пульсовой волны. В качестве диагностического показателя служит спектральный индекс, определяемый как отношений амплитуд первых двух гармоник спектра. Исследовано влияние погрешности измерений амплитуды пульсовой волны на погрешность определения различных показателей морфологического анализа пульсовой волны.</p></abstract><trans-abstract xml:lang="en"><p>This article is devoted to analysis of the noise immunity of pulse wave’s contour analysis. Different approaches to the implementation of the pulse wave’s contour analysis were considered. It was demonstrated, that classical approach for the morphological analysis of the pulse wave based on using stiffness index and reflection index do not provide sufficient diagnostic accuracy due to the instability of the maximum detection of the reflected wave. The technique of contour analysis based on spectral transformation of replicated fragments of the pulse wave was proposed. As a diagnostic index the ratio of the amplitudes of the first two harmonics of the spectrum was used. The influence of uncertainty measurement of the pulse wave amplitude on determining the accuracy of the morphological analysis of the pulse wave realized by different methods was researched.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>пульсовая волна</kwd><kwd>контурный анализ</kwd><kwd>спектральное преобразование</kwd><kwd>скрининг-диагностика</kwd><kwd>pulse wave</kwd><kwd>contour analysis</kwd><kwd>spectral transform</kwd><kwd>screening and diagnostics</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Expert Consensus Document on arterial stiffness: methodological issues and clinical applications // European Heart Journal. 2006. V. 27 (21). P. 2588-2605.</mixed-citation><mixed-citation xml:lang="en">Expert Consensus Document on arterial stiffness: methodological issues and clinical applications // European Heart Journal. 2006. V. 27 (21). P. 2588-2605.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Millasseau S. C., Ritter J. M., Takazawa K., Chowienczyk P. J. Contour analysis of the photoplethysmographic pulse measured at the finger // Hypertension. 2006. V. 8. No. 8. P. 1449-1456.</mixed-citation><mixed-citation xml:lang="en">Millasseau S. C., Ritter J. M., Takazawa K., Chowienczyk P. J. Contour analysis of the photoplethysmographic pulse measured at the finger // Hypertension. 2006. V. 8. No. 8. P. 1449-1456.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Федотов А. А., Акулов С. А. Измерительные преобразователи биомедицинских сигналов систем клинического мониторинга. М.: Радио и связь, 2013.</mixed-citation><mixed-citation xml:lang="en">Федотов А. А., Акулов С. А. Измерительные преобразователи биомедицинских сигналов систем клинического мониторинга. М.: Радио и связь, 2013.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Weber T., Auer J., O’Rourke M. F., Kvas E., Lassnig E., Berent R., Eber B. Arterial Stiffness, Wave Reflections, and the Risk of Coronary Artery Disease // Circulation. 2004. V. 109. No. 4. P. 184-189.</mixed-citation><mixed-citation xml:lang="en">Weber T., Auer J., O’Rourke M. F., Kvas E., Lassnig E., Berent R., Eber B. Arterial Stiffness, Wave Reflections, and the Risk of Coronary Artery Disease // Circulation. 2004. V. 109. No. 4. P. 184-189.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Millasseau S. C., Kelly R. P., Ritter J. M., Chowienczyk P. J. Determination of age-related increases in large artery stiffness by digital pulse contour analysis // Clinical Science. 2002. V. 103. No. 4. P. 371-377.</mixed-citation><mixed-citation xml:lang="en">Millasseau S. C., Kelly R. P., Ritter J. M., Chowienczyk P. J. Determination of age-related increases in large artery stiffness by digital pulse contour analysis // Clinical Science. 2002. V. 103. No. 4. P. 371-377.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Калакутский Л. И., Федотов А. А. Диагностика дисфункции сосудистого эндотелия методом контурного анализа пульсовой волны // Известия Южного федерального университета. Технические науки. 2009. № 9. С. 93-98.</mixed-citation><mixed-citation xml:lang="en">Калакутский Л. И., Федотов А. А. Диагностика дисфункции сосудистого эндотелия методом контурного анализа пульсовой волны // Известия Южного федерального университета. Технические науки. 2009. № 9. С. 93-98.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Рангайян Р. М. Анализ биомедицинских сигналов. Практический подход. М.: ФИЗМАТЛИТ, 2007.</mixed-citation><mixed-citation xml:lang="en">Рангайян Р. М. Анализ биомедицинских сигналов. Практический подход. М.: ФИЗМАТЛИТ, 2007.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Федотов А. А. Амплитудно-временно́й метод детектирования характерных точек сигнала пульсовой волны // Медицинская техника. 2012. № 6. С. 22-28.</mixed-citation><mixed-citation xml:lang="en">Федотов А. А. Амплитудно-временно́й метод детектирования характерных точек сигнала пульсовой волны // Медицинская техника. 2012. № 6. С. 22-28.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Fedotov A. A., Akulova A. S., Akulov S. A., Reshetnikova M. A. Novel spectral approach for pulse waves contour analysis // IFMBE Proceedings of the 16th Int. Conf. on Biomedical Engineering. 2017. V. 61. P. 16-20.</mixed-citation><mixed-citation xml:lang="en">Fedotov A. A., Akulova A. S., Akulov S. A., Reshetnikova M. A. Novel spectral approach for pulse waves contour analysis // IFMBE Proceedings of the 16th Int. Conf. on Biomedical Engineering. 2017. V. 61. P. 16-20.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Новицкий П. В., Зограф И. А. Оценка погрешностей результатов измерений. М.: Энергоатомиздат, 1991.</mixed-citation><mixed-citation xml:lang="en">Новицкий П. В., Зограф И. А. Оценка погрешностей результатов измерений. М.: Энергоатомиздат, 1991.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
