<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.32446/0368-1025it.2018-56-58</article-id><article-id custom-type="elpub" pub-id-type="custom">izmertech-923</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ИЗМЕРЕНИЯ ИОНИЗИРУЮЩИХ ИЗЛУЧЕНИЙ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>IONIZING RADIATION MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>Использование сцинтиллятора на основе литиевого стекла для регистрации нейтронного излучения</article-title><trans-title-group xml:lang="en"><trans-title>Using a scintillator based lithium glass for neutron radiation</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Фёдоров</surname><given-names>С. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Fedorov</surname><given-names>S. .</given-names></name></name-alternatives><email xlink:type="simple">fedorov911@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Всероссийский научно-исследовательский институт физико-технических и радиотехнических измерений Национальный исследовательский ядерный университет «МИФИ»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Federal State Unitary Enterprise Russian Metrological Institute of Technical Physics and Radio Engineering National Research Nuclear University «MEPhI»</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>12</issue><fpage>56</fpage><lpage>58</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/923">https://www.izmt.ru/jour/article/view/923</self-uri><abstract><p>Выполнены исследования, заключающиеся в повышении точности измерений энергии нейтронных полей и усовершенствовании спектрометрического анализа полей нейтронного излучения с применением сцинциляционных детекторов. Рассмотрено применение сцинтилляционного детектора на основе литиевых стекол6Li2O различных диаметров и толщин для регистрации энергии нейтронного излучения, составившей 0,4-15·106 В. Проведены сравнения основных характеристик данного сцинтилляционного детектора и результатов измерений, полученных с его помощью, с характеристиками и результатами измерений сцинтиллятора на основе LiI(Eu). Показано, что для работы сцинтилляционного детектора использовались шаровые замедлители диаметрами 70-300 мм.</p></abstract><trans-abstract xml:lang="en"><p>The completed research consists in increasing the accuracy of energy measurements of neutron fields and the improvement of spectrometric analysis of neutron radiation fields with the use of scintillation detectors. The article discusses the use of a scintillation detector based on lithium glasses6Li2O of various diameters and thicknesses for recording neutron radiation with an energy from 0.4 eV to 15 MeV. Comparisons were also made of the main characteristics and measurement results with a LiI (Eu) based scintillator. The scintillator was used in conjunction with a set of ball retarders with a diameter of 70 to 300 mm.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>источники нейтронного излучения</kwd><kwd>источники гамма-излучения</kwd><kwd>сцинтилляционные детекторы</kwd><kwd>литиевое стекло</kwd><kwd>шаровые замедлители</kwd><kwd>тепловые нейтроны</kwd><kwd>sources of neutron radiation</kwd><kwd>sources of gamma radiation</kwd><kwd>scintillation detectors</kwd><kwd>lithium glass</kwd><kwd>spherical moderators</kwd><kwd>thermal neutrons</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Crane T. W., Baker M. P. Neutron Detectors in Passive Nondestructive Assay of Nuclear materials / ed. by D. Reilly/ Nuclear Regulatory Commission. USA: Los Alamos National Laboratory, 1991.</mixed-citation><mixed-citation xml:lang="en">Crane T. W., Baker M. P. Neutron Detectors in Passive Nondestructive Assay of Nuclear materials / ed. by D. Reilly/ Nuclear Regulatory Commission. USA: Los Alamos National Laboratory, 1991.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Murray R. B. Use of lii(eu) as a scintillation detector and spectrometer for fast neutrons. USA, Tennessee: Oak Ridge National Laboratory T, Oak Ridge, 1957.</mixed-citation><mixed-citation xml:lang="en">Murray R. B. Use of lii(eu) as a scintillation detector and spectrometer for fast neutrons. USA, Tennessee: Oak Ridge National Laboratory T, Oak Ridge, 1957.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Kononov V. N., Poletaev E. D., Bohovko M. V., Kazakov l. E., Timohov V. M., Dyachenko P. P., Kutsaeva l. S., Seregina E. A. Neutron detection efficiency of a thick lithium glass detector. USSR, Obninsk: Institute of Physics and Power Engineering, 1984.</mixed-citation><mixed-citation xml:lang="en">Kononov V. N., Poletaev E. D., Bohovko M. V., Kazakov l. E., Timohov V. M., Dyachenko P. P., Kutsaeva l. S., Seregina E. A. Neutron detection efficiency of a thick lithium glass detector. USSR, Obninsk: Institute of Physics and Power Engineering, 1984.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Bramblett R., Ewing R., Bonner T. A new type of neutron spectrometer. USA, Houston Texas: The Rice University, 1960.</mixed-citation><mixed-citation xml:lang="en">Bramblett R., Ewing R., Bonner T. A new type of neutron spectrometer. USA, Houston Texas: The Rice University, 1960.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Масляев П. Ф., Фёдоров С. Г. Универсальный спектрометр нейтронов // АНРИ. 2017. № 2 (89). С. 12-17.</mixed-citation><mixed-citation xml:lang="en">Масляев П. Ф., Фёдоров С. Г. Универсальный спектрометр нейтронов // АНРИ. 2017. № 2 (89). С. 12-17.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Масляев П. Ф., Цуриев С. -М. Ш. Совершенствование системы обеспечения единства измерений дозиметрических величин в полях нейтронного излучения // Измерительная техника. 2011. № 4. C. 9-13.</mixed-citation><mixed-citation xml:lang="en">Масляев П. Ф., Цуриев С. -М. Ш. Совершенствование системы обеспечения единства измерений дозиметрических величин в полях нейтронного излучения // Измерительная техника. 2011. № 4. C. 9-13.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
