<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">izmertech-681</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ФИЗИКО-ХИМИЧЕСКИЕ ИЗМЕРЕНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>PHYSICOCHEMICAL MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>Особенности проведения испытаний на герметичность миниатюрных газонаполненных разрядников в условиях нестабильной работы ионного источника масс-спектрометра</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бушин</surname><given-names>С. А.</given-names></name></name-alternatives><email xlink:type="simple">vniia4@vniia.ru; 2009-01-07@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Всероссийский научно-исследовательский институт автоматики им. Н.Л. Духова</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>4</issue><fpage>62</fpage><lpage>69</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/681">https://www.izmt.ru/jour/article/view/681</self-uri><abstract><p>Представлены результаты по отработке методики контроля герметичности миниатюрных газонаполненных разрядников, что обусловлено проблемой, касающейся нестабильности в работе ионного источника масс-спектрометра из-за выработавшего свой ресурс катода. Рассмотрены теоретические и практические подходы, способствующие устранению данной проблемы. Предложены решения задач, в том числе методические, направленные на минимизацию потери полезной масс-спектрометрической информации в условиях временного понижения чувствительности газоанализатора. Показана необходимость принятия мер по предупреждению возникновения нехарактерных искажений регистрируемых масс-спектрограмм.</p></abstract><trans-abstract xml:lang="en"><p>The paper presents the results of the development of the technique for checking the tightness of miniature gas-filled spark gaps. Mainly, this is due to the problem of the presence of instability in the operation of the ion source of the mass spectrometer, because of the cathode that has exhausted its resource. Wherein, theoretical and practical approaches to solving this problem are considered. Solutions are proposed, including methodological ones, aimed at minimizing the loss of useful mass spectrometric information in conditions of a temporary decrease in the sensitivity of the gas analyzer. The necessity of taking certain measures to prevent the appearance of uncharacteristic distortions of the recorded mass spectrograms is shown.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>ионный источник</kwd><kwd>катод</kwd><kwd>деградационный отказ</kwd><kwd>математическое моделирование</kwd><kwd>способ накопления</kwd><kwd>газонаполненные приборы</kwd><kwd>вакуумная установка финишного контроля герметичности</kwd><kwd>квадрупольный масс-спектрометр</kwd><kwd>изотропность</kwd><kwd>трибологический фактор</kwd><kwd>ion source</kwd><kwd>cathode</kwd><kwd>degradation failure</kwd><kwd>mathematical modeling</kwd><kwd>method of accumulation</kwd><kwd>gas-filled devices</kwd><kwd>vacuum installation for the final leak test</kwd><kwd>quadrupole mass spectrometer</kwd><kwd>isotropy</kwd><kwd>tribological factor</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бушин С. А. Методика высокочувствительного контроля герметичности газонаполненных разрядников по истечению неона // Вакуумная техника и технология. 2012. Т. 22. № 2. С. 98-99.</mixed-citation><mixed-citation xml:lang="en">Бушин С. А. Методика высокочувствительного контроля герметичности газонаполненных разрядников по истечению неона // Вакуумная техника и технология. 2012. Т. 22. № 2. С. 98-99.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 24054-80. Методы испытаний на герметичность. Общие требования. М.: «Издательство стандартов», 1987.</mixed-citation><mixed-citation xml:lang="en">ГОСТ 24054-80. Методы испытаний на герметичность. Общие требования. М.: «Издательство стандартов», 1987.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">ОСТ 11 0808-96. Контроль неразрушающий. Методы течеискания.</mixed-citation><mixed-citation xml:lang="en">ОСТ 11 0808-96. Контроль неразрушающий. Методы течеискания.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Бушин C. А. Особенности методики контроля герметичности газонаполненных разрядников // Вакуумная техника и технологии - 2017: Труды 24-й Всерос. науч.-техн. конф. СПб.: Изд-во СПбГЭТУ «ЛЭТИ», 2017.</mixed-citation><mixed-citation xml:lang="en">Бушин C. А. Особенности методики контроля герметичности газонаполненных разрядников // Вакуумная техника и технологии - 2017: Труды 24-й Всерос. науч.-техн. конф. СПб.: Изд-во СПбГЭТУ «ЛЭТИ», 2017.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Вентцель Е. С. Теория вероятностей. М.: Наука, 1964.</mixed-citation><mixed-citation xml:lang="en">Вентцель Е. С. Теория вероятностей. М.: Наука, 1964.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Владимиров Г. Г. Физическая электроника. Ч. 1. Термоэлектронная эмиссия: Учебно-методическое пособие. Санкт-Петербург, 2007.</mixed-citation><mixed-citation xml:lang="en">Владимиров Г. Г. Физическая электроника. Ч. 1. Термоэлектронная эмиссия: Учебно-методическое пособие. Санкт-Петербург, 2007.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
