<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">izmertech-627</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Определение положения центра лазерного пучка при 
превышении динамического диапазона матричного
 приемника</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Орлов</surname><given-names>Д. А.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Неверова</surname><given-names>Е. А.</given-names></name></name-alternatives><email xlink:type="simple">elneverova@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Московский энергетический институт (технический университет), Москва</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2010</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>10</issue><fpage>39</fpage><lpage>42</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/627">https://www.izmt.ru/jour/article/view/627</self-uri><abstract><p>Рассмотрено влияние насыщения матричного приемника при определении координат центра лазерного пучка методом взвешивания. Исследована зависимость точности измерений от размера пучка и числа насыщенных пикселов на фотоприемной матрице. Проведено численное моделирование выходного сигнала. Модельные расчеты сопоставлены с результатами эксперимента.</p></abstract><trans-abstract xml:lang="en"><p>The influence of focal plane array saturation at subpixel centroid estimation of near point laser target images have been investigated. The measurement results were compared with mathematical simulation. The influence of image size and number of saturated pixels on measurements precision was studied. The new algorithm has been optimized for improvement of the laser systems dynamic range.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>лазерный гауссов пучок</kwd><kwd>матричный фотоприемник</kwd><kwd>метод взвешивания</kwd><kwd>центроидные алгоритмы</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Gaussian shape laser</kwd><kwd>saturated image</kwd><kwd>subpixel resolution</kwd><kwd>centroid algorithms</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Устинов Н. Д. Лазерная локация. М.: Машиностроение, 1984.</mixed-citation><mixed-citation xml:lang="en">Устинов Н. Д. Лазерная локация. М.: Машиностроение, 1984.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Welch S. S. Effects of Window Size and Shape on Accuracy of Subpixel Centroid Estimation of Target Images. WU 590-14-11-02, NASA techn. paper 3331. Oct. 1993.</mixed-citation><mixed-citation xml:lang="en">Welch S. S. Effects of Window Size and Shape on Accuracy of Subpixel Centroid Estimation of Target Images. WU 590-14-11-02, NASA techn. paper 3331. Oct. 1993.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Савченко Е. В., Разумов Л. А., Ринкевичюс Б. С. Определение координат центра гауссова пучка с помощью матричного приемника методом взвешивания // Измерительная техника. 2003. № 12. С. 11 - 14;</mixed-citation><mixed-citation xml:lang="en">Савченко Е. В., Разумов Л. А., Ринкевичюс Б. С. Определение координат центра гауссова пучка с помощью матричного приемника методом взвешивания // Измерительная техника. 2003. № 12. С. 11 - 14;</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Akondi Vyas, Roopashree M. B., Prasad B. R. Performance of Centroiding Algorithms at Low Light Level Conditions in Adaptive Optics // Proc. Intern. Conf. Advances in Recent Technologies in Communication and Computting. Kottayam (Kerala, India), 2009. P. 366-369.</mixed-citation><mixed-citation xml:lang="en">Akondi Vyas, Roopashree M. B., Prasad B. R. Performance of Centroiding Algorithms at Low Light Level Conditions in Adaptive Optics // Proc. Intern. Conf. Advances in Recent Technologies in Communication and Computting. Kottayam (Kerala, India), 2009. P. 366-369.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Васильев Д. В. К вопросу оптимизации корреляционных измерителей скорости // Радиотехнические тетради. М.: Изд-во МЭИ, 2000. № 20. С. 7-14.</mixed-citation><mixed-citation xml:lang="en">Васильев Д. В. К вопросу оптимизации корреляционных измерителей скорости // Радиотехнические тетради. М.: Изд-во МЭИ, 2000. № 20. С. 7-14.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Pozin A. Using of sub pixel line extraction methods in non-contact measure systems // Intern. Conf. Graphicon 2004. Moscow (Russia), &lt;http://www.graphicon.ru/&gt;</mixed-citation><mixed-citation xml:lang="en">Pozin A. Using of sub pixel line extraction methods in non-contact measure systems // Intern. Conf. Graphicon 2004. Moscow (Russia), &lt;http://www.graphicon.ru/&gt;</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Евтихиева О. А., Расковская И. Л., Ринкевичюс Б. С. Лазерная рефрактография. М.: ФИЗМАТЛИТ, 2008.</mixed-citation><mixed-citation xml:lang="en">Евтихиева О. А., Расковская И. Л., Ринкевичюс Б. С. Лазерная рефрактография. М.: ФИЗМАТЛИТ, 2008.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Leroux C., Dainty C. Estimation of centroid positions with a matched-filter algorithm: relevance for aberrometry of the eye // Opt. Soci. Am. Optics Express. 2010. V. 18. Iss. 2. P. 1197-1206.</mixed-citation><mixed-citation xml:lang="en">Leroux C., Dainty C. Estimation of centroid positions with a matched-filter algorithm: relevance for aberrometry of the eye // Opt. Soci. Am. Optics Express. 2010. V. 18. Iss. 2. P. 1197-1206.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Червонкин А. П. Оптическая система многоспектральной моноапертурной оптико-локационной станции самолета с динамической стабилизацией осей функциональных каналов: Автореф. дис. на соиск. учен. степ. канд. техн. наук. М., 2006.</mixed-citation><mixed-citation xml:lang="en">Червонкин А. П. Оптическая система многоспектральной моноапертурной оптико-локационной станции самолета с динамической стабилизацией осей функциональных каналов: Автореф. дис. на соиск. учен. степ. канд. техн. наук. М., 2006.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Гультяев А. Визуальное моделирование в среде MATLAB: Учеб. курс. СПб.: Питер, 2000.</mixed-citation><mixed-citation xml:lang="en">Гультяев А. Визуальное моделирование в среде MATLAB: Учеб. курс. СПб.: Питер, 2000.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Ohta Jun. Smart CMOS image sensors and applications. N.Y.: CRC Press Taylor &amp; Francis Group, 2008.</mixed-citation><mixed-citation xml:lang="en">Ohta Jun. Smart CMOS image sensors and applications. N.Y.: CRC Press Taylor &amp; Francis Group, 2008.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Неверова Е. А., Орлов Д. А. Предварительная калибровка КМОП InGaAs матрицы для повышения качества изображения // Радиоэлектроника, электротехника и энергетика: Тез. докл. XVI Междунар. науч.-техн. конф. студентов и аспирантов. М: Изд. дом МЭИ, 2010. Т. 1. С. 186.</mixed-citation><mixed-citation xml:lang="en">Неверова Е. А., Орлов Д. А. Предварительная калибровка КМОП InGaAs матрицы для повышения качества изображения // Радиоэлектроника, электротехника и энергетика: Тез. докл. XVI Междунар. науч.-техн. конф. студентов и аспирантов. М: Изд. дом МЭИ, 2010. Т. 1. С. 186.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
