<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">izmertech-456</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МЕДИЦИНСКИЕ И БИОЛОГИЧЕСКИЕ ИЗМЕРЕНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>MEDICAL AND BIOLOGICAL MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>Пламенно-фотометрические и потенциометрические методики выполнения измерений концентрации натрия в крови</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бузановский</surname><given-names>В. А.</given-names></name></name-alternatives><email xlink:type="simple">vab1960@rambler.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>ООО Компания «Безопасность»</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>3</issue><fpage>64</fpage><lpage>67</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/456">https://www.izmt.ru/jour/article/view/456</self-uri><abstract><p>Исследование крови человека выполняют по многочисленным показателям, одним из которых является концентрация натрия. Рассмотрены пламенно-фотометрические и потенциометрические методики, предназначенные для определения концентрации натрия в плазме, сыворотке и цельной крови. Представлены краткие сведения об указанных методиках и результатах их сравнительных испытаний.</p></abstract><trans-abstract xml:lang="en"><p>Research of human blood is carried out for numerous parameters. One of them is sodium concentration. In this article flame photometric and potentiometric procedures for determination of sodium concentration in plasma, serum and whole blood are described. Brief data on these procedures and results of their comparative tests are presented.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>пламенно-фотометрическая</kwd><kwd>потенциометрическая</kwd><kwd>методика выполнения измерений</kwd><kwd>концентрация</kwd><kwd>натрий</kwd><kwd>кровь</kwd><kwd>flame photometric</kwd><kwd>potentiometric</kwd><kwd>procedure of measurements</kwd><kwd>concentration</kwd><kwd>sodium</kwd><kwd>blood</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Drayer R.L. Semimicro flame photometry of serum sodium and potassium // Clin. Chem. 1956. V. 2. № 2. P. 112-116.</mixed-citation><mixed-citation xml:lang="en">Drayer R.L. Semimicro flame photometry of serum sodium and potassium // Clin. Chem. 1956. V. 2. № 2. P. 112-116.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Oesch U., Ammann D., Simon W. Ion-selective membrane electrodes for clinical use // Clin. Chem. 1986. V. 32. № 8. P. 1448-1459.</mixed-citation><mixed-citation xml:lang="en">Oesch U., Ammann D., Simon W. Ion-selective membrane electrodes for clinical use // Clin. Chem. 1986. V. 32. № 8. P. 1448-1459.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Ladenson J.H. Evaluation of an instrument (Nova-1) for direct potentiometric analysis of sodium and potassium in blood and their indirect potentiometric determination in urine // Clin. Chem. 1979. V. 25. № 5. P. 757-763.</mixed-citation><mixed-citation xml:lang="en">Ladenson J.H. Evaluation of an instrument (Nova-1) for direct potentiometric analysis of sodium and potassium in blood and their indirect potentiometric determination in urine // Clin. Chem. 1979. V. 25. № 5. P. 757-763.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Koch D.D., Parrish D., Ladenson J.H. Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca // Clin. Chem. 1983. V. 29. № 6. P. 1090-1092.</mixed-citation><mixed-citation xml:lang="en">Koch D.D., Parrish D., Ladenson J.H. Evaluation of a direct potentiometric method for sodium and potassium used in the Du Pont aca // Clin. Chem. 1983. V. 29. № 6. P. 1090-1092.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Lustgarten J.A., Wenk R.E., Byrd C., Hall B. Evaluation of an automated selective-ion electrolyte analyzer for measuring Na+, K+, and C1- in serum // Clin. Chem. 1974. V. 20. № 9. P. 1217-1221.</mixed-citation><mixed-citation xml:lang="en">Lustgarten J.A., Wenk R.E., Byrd C., Hall B. Evaluation of an automated selective-ion electrolyte analyzer for measuring Na+, K+, and C1- in serum // Clin. Chem. 1974. V. 20. № 9. P. 1217-1221.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Ng R.H., Altaffer M., Ito R., Statland B.E. The Technicon RA-1000 evaluated for measuring sodium, potassium, chloride, and carbon dioxide // Clin. Chem. 1985. V. 31. № 3. P. 435-438.</mixed-citation><mixed-citation xml:lang="en">Ng R.H., Altaffer M., Ito R., Statland B.E. The Technicon RA-1000 evaluated for measuring sodium, potassium, chloride, and carbon dioxide // Clin. Chem. 1985. V. 31. № 3. P. 435-438.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Guagnellini E., Spagliardi G., Bernardi G., Stella P. Reliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements // Clin. Chem. 1988. V. 34. № 4. P. 746-748.</mixed-citation><mixed-citation xml:lang="en">Guagnellini E., Spagliardi G., Bernardi G., Stella P. Reliability of IL Monarch ion-selective electrode module for sodium, potassium, and chloride measurements // Clin. Chem. 1988. V. 34. № 4. P. 746-748.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Anker P., Jenny H.-B., Wuthier U., Asper R., Ammann D., Simon W. Potentiometry of Na in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode // Clin. Chem. 1983. V. 29. № 8. P. 1508-1512.</mixed-citation><mixed-citation xml:lang="en">Anker P., Jenny H.-B., Wuthier U., Asper R., Ammann D., Simon W. Potentiometry of Na in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode // Clin. Chem. 1983. V. 29. № 8. P. 1508-1512.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Sibbald A., Covington A.K., Carter R.F. Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function Chem FET integrated-circuit sensor // Clin. Chem. 1984. V. 30. № 1. P. 135-137.</mixed-citation><mixed-citation xml:lang="en">Sibbald A., Covington A.K., Carter R.F. Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function Chem FET integrated-circuit sensor // Clin. Chem. 1984. V. 30. № 1. P. 135-137.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Ng R.H., Altaffer M., Statland B.E. Assay of sodium, potassium, and ionized calcium in whole blood with the ChemPro-1000 // Clin. Chem. 1986. V. 32. № 11. P. 2103.</mixed-citation><mixed-citation xml:lang="en">Ng R.H., Altaffer M., Statland B.E. Assay of sodium, potassium, and ionized calcium in whole blood with the ChemPro-1000 // Clin. Chem. 1986. V. 32. № 11. P. 2103.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Jack R.M., Noble W. Generation 04 sodium slides and generation 04 reference fluid evaluated for use with the Ektachem 400 analyzer // Clin. Chem. 1987. V. 33. № 6. P. 845-847.</mixed-citation><mixed-citation xml:lang="en">Jack R.M., Noble W. Generation 04 sodium slides and generation 04 reference fluid evaluated for use with the Ektachem 400 analyzer // Clin. Chem. 1987. V. 33. № 6. P. 845-847.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
