<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.32446/0368-1025it.2026-1-12-21</article-id><article-id custom-type="elpub" pub-id-type="custom">izmertech-2420</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ГОСУДАРСТВЕННЫЕ ЭТАЛОНЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>STATE STANDARDS</subject></subj-group></article-categories><title-group><article-title>Государственный первичный эталон единиц мощности, интенсивности и давления ультразвука в воде ГЭТ 169-2025</article-title><trans-title-group xml:lang="en"><trans-title>State primary standard of power, intensity, and pressure of ultrasound in water GET 169-2025</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7674-8010</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кузнецов</surname><given-names>С. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Kuznetsov</surname><given-names>S. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Сергей Игоревич Кузнецов, младший научный сотрудник</p><p>141570, Московская обл., г. Солнечногорск, пгт Менделеево, промзона ФГУП ВНИИФТРИ, к. 11</p></bio><bio xml:lang="en"><p>Sergey I. Kuznetsov, Junior Researcher</p><p>141570, Moscow Region, Solnechnogorsk, Mendeleevo settlement, industrial zone of FSUE VNIIFTRI, building 11</p></bio><email xlink:type="simple">sergantex@vniiftri.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2912-9484</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лукин</surname><given-names>Г. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Lukin</surname><given-names>G. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Георгий Сергеевич Лукин, начальник лаборатории</p><p>141570, Московская обл., г. Солнечногорск, пгт Менделеево, промзона ФГУП ВНИИФТРИ, к. 11</p></bio><bio xml:lang="en"><p>Georgiy S. Lukin, Head of Laboratory</p><p>141570, Moscow Region, Solnechnogorsk, Mendeleevo settlement, industrial zone of FSUE VNIIFTRI, building 11</p></bio><email xlink:type="simple">lukin@vniiftri.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Всероссийский научно-исследовательский институт физико-технических и радиотехнических измерений</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Russian Metrological Institute of Technical Physics and Radio Engineering</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>14</day><month>03</month><year>2026</year></pub-date><volume>75</volume><issue>1</issue><fpage>12</fpage><lpage>21</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/2420">https://www.izmt.ru/jour/article/view/2420</self-uri><abstract><p>Распространение ультразвуковых медицинских приборов и развитие ультразвуковых методов диагностики и лечения привели к необходимости метрологического контроля широкого спектра параметров акустического выхода ультразвукового медицинского оборудования, таких как давление и интенсивность ультразвука. C целью обеспечения единства измерений в области высокочастотных (0,5–20 МГц) гидроакустических измерений, а также реализации метрологической прослеживаемости результатов измерений интенсивности и давления, полученных с применением соответственно измерителей параметров ультразвукового поля и высокочастотных гидрофонов, усовершенствован Государственный первичный эталон единицы мощности ультразвука в воде ГЭТ 169-2019. В результате совершенствования утверждён Государственный первичный эталон единиц мощности, интенсивности и давления ультразвука в воде ГЭТ 169-2025, в состав которого вошли две новые установки: установка для воспроизведения и передачи единицы интенсивности ультразвука в воде УЭВЧ-1 и установка для воспроизведения и передачи единицы давления ультразвука в воде УЭВЧ-2. Расширение перечня воспроизводимых с помощью ГЭТ 169-2025 единиц позволяет осуществлять метрологическую прослеживаемость результатов измерений мощности, интенсивности и давления ультразвука в воде, а также прослеживаемость приборов, предназначенных для измерений и контроля параметров акустического выхода ультразвукового медицинского и иного оборудования. В Государственную поверочную схему для средств измерений мощности ультразвука в воде в диапазоне частот от 0,5 до 20 МГц внесены изменения, отражающие новые возможности ГЭТ 169-2025 и позволяющие решать проблемы распространения рабочих эталонов в метрологические центры Российской Федерации.</p></abstract><trans-abstract xml:lang="en"><p>The proliferation of ultrasound medical devices and the development of ultrasound diagnostic and therapeutic methods have necessitated metrological control of a wide range of ultrasound medical equipment acoustic output parameters, such as ultrasound pressure and intensity. To ensure the uniformity of high-frequency (0.5–20 MHz) hydroacoustic measurements, as well as to implement metrological traceability of intensity and pressure measurement results obtained using ultrasonic field parameter meters and high-frequency hydrophones, respectively, the State primary standard of the unit of ultrasound power in water, GET 169-2019, has been improved. As a result of these improvements, the State primary standard of the units of ultrasound power, intensity, and pressure in water, GET 169-2025, has been approved. This standard includes two new units: the URTU-1 unit for reproducing and transmitting the unit of ultrasound intensity in water and the URTU-2 unit for reproducing and transmitting the unit of ultrasound pressure in water. The expansion of the list of units reproducible using GET 169-2025 enables metrological traceability of the results of ultrasound power, intensity, and pressure measurements in water, and therefore of devices designed to measure and control the acoustic output parameters of medical ultrasound and other equipment. Amendments have been made to the state verification scheme for ultrasound power measuring instruments in the frequency range from 0.5 to 20 MHz, reflecting the new capabilities of GET 169-2025 and addressing the challenges of distributing working standards to metrology centers across the Russian Federation.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>гидрофон</kwd><kwd>мощность ультразвука</kwd><kwd>давление ультразвука</kwd><kwd>интенсивность</kwd><kwd>неисключённая&#13;
систематическая погрешность</kwd><kwd>неопределённость измерений</kwd><kwd>ультразвуковой пучок</kwd><kwd>ультразвуковое медицинское&#13;
оборудование</kwd></kwd-group><kwd-group xml:lang="en"><kwd>hydrophone</kwd><kwd>ultrasound power</kwd><kwd>ultrasound pressure</kwd><kwd>intensity</kwd><kwd>non-excluded systematic error</kwd><kwd>measurement&#13;
uncertainty</kwd><kwd>ultrasound beam</kwd><kwd>ultrasound medical equipment</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Авторы заявляют, что во время подготовки данной рукописи не было получено никаких средств, грантов или другой поддержки.</funding-statement><funding-statement xml:lang="en">The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Rajeet Chandan, Sourabh Mehta, Rinti Banerjee. Ultrasound-responsive carriers for therapeutic applications. ACS Biomaterials Science and Engineering, 6(9), 4731–4747 (2020). https://doi.org/10.1021/acsbiomaterials.9b01979 ; https://elibrary.ru/pdqgqe</mixed-citation><mixed-citation xml:lang="en">Rajeet Chandan, Sourabh Mehta, Rinti Banerjee. Ultrasound-responsive carriers for therapeutic applications. ACS Biomaterials Science and Engineering, 6(9), 4731–4747 (2020). https://doi.org/10.1021/acsbiomaterials.9b01979 ; https://elibrary.ru/pdqgqe</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Dubinsky T. J., Cuevas C., Dighe M. K., Kolokythas O., Hwang J. H. High-intensity focused ultrasound: current potential and oncologic applications. American Journal of Roentgenology, 190(1), 191–199 (2008). https://doi.org/10.2214/AJR.07.2671 ; https://elibrary.ru/lygych</mixed-citation><mixed-citation xml:lang="en">Dubinsky T. J., Cuevas C., Dighe M. K., Kolokythas O., Hwang J. H. High-intensity focused ultrasound: current potential and oncologic applications. American Journal of Roentgenology, 190(1), 191–199 (2008). https://doi.org/10.2214/AJR.07.2671 ; https://elibrary.ru/lygych</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Preston R. C. Metrology and traceability in medical ultrasound – Experiences and lessons for the future. Journal of Physics: Conference Series, 1, 1 (2004). https://doi.org/10.1088/1742-6596/1/1/001</mixed-citation><mixed-citation xml:lang="en">Preston R. C. Metrology and traceability in medical ultrasound – Experiences and lessons for the future. Journal of Physics: Conference Series, 1, 1 (2004). https://doi.org/10.1088/1742-6596/1/1/001</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Esteban-Temprano Á., De Castro-Asensio I., Delgado-San Martín L. et al. Emerging innovations in health metrology for diagnostic imaging, Measurement: Sensors, 38(Suppl.), 101649 (2025). https://doi.org/10.1016/j.measen.2024.101649</mixed-citation><mixed-citation xml:lang="en">Esteban-Temprano Á., De Castro-Asensio I., Delgado-San Martín L. et al. Emerging innovations in health metrology for diagnostic imaging, Measurement: Sensors, 38, 101649 (2025). https://doi.org/10.1016/j.measen.2024.101649</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Petchpong P. Verification of Medical Measuring Device on Therapeutic Ultrasound Using Metrological Traceability. 2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE), Hiroshima, Japan, pp. 817–822 (2019). https://doi.org/10.23919/SICE.2019.8859967</mixed-citation><mixed-citation xml:lang="en">Petchpong P. Verifi cation of Medical Measuring Device on Therapeutic Ultrasound Using Metrological Traceability. 2019 58th Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE), Hiroshima, Japan, pp. 817–822 (2019). https://doi.org/10.23919/SICE.2019.8859967</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Souza R. M., Alvarenga A. V., Petrella L. I. et al. Metrological assessment of image quality in ultrasonic medical diagnostic equipment. Research on Biomedical Engineering, 36, 379–397 (2020). https://doi.org/10.1007/s42600-020-00078-4</mixed-citation><mixed-citation xml:lang="en">Souza R. M., Alvarenga A. V., Petrella L. I. et al. Metrological assessment of image quality in ultrasonic medical diagnostic equipment. Research on Biomedical Engineering, 36, 379–397 (2020). https://doi.org/10.1007/s42600-020-00078-4</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Измерительные возможности медицинских приборов ультразвуковой диагностики. Законодательная и прикладная метрология, (1), 47–55 (2006). https://elibrary.ru/pbnntx</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. Measuring capabilities of medical ultrasound diagnostic devices. Legal and Applied Metrology, (1), 47–55 (2006). (In Russ.) https://elibrary.ru/pbnntx</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Контроль технических характеристик медицинских эхоимпульсных приборов ультразвуковой диагностики. Законодательная и прикладная метрология, (4), 13–17 (2006). https://elibrary.ru/pbnxcp</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. Monitoring the technical characteristics of medical echo-pulse ultrasound diagnostic devices. Legal and Applied Metrology, (4), 13–17 (2006). (In Russ.) https://elibrary.ru/pbnxcp</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. О нормативном обеспечении разработки и применения аппаратов для ультразвуковой терапии. Законодательная и прикладная метрология, (6), 25–30 (2006). https://elibrary.ru/pbnxur</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. On regulatory support for the development and use of devices for ultrasound therapy. Legal and Applied Metrology, (6), 25–30 (2006). (In Russ.) https://elibrary.ru/pbnxur</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Контроль эффективности и безопасности медицинского ультразвукового оборудования в процессе эксплуатации. Мир измерений, (12), 10–18 (2012). https://elibrary.ru/pidqll</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. In-service control of efficiency and safety of ultrasonic medical equipment. World of Measurements, (12), 10–18 (2012). (In Russ.) https://elibrary.ru/pidqll</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Метрологические проблемы применения ультразвука в физиотерапии. Альманах современной метрологии, (4), 152–193 (2015). https://elibrary.ru/vdtxhb</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. Metrological problems of ultrasound application in physiotherapy. Al’manac of Modern Metrology, (4), 152–193 (2015). (In Russ.) https://elibrary.ru/vdtxhb</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Исаев А. Е., Кузнецов С. И., Ломовацкий Ю. А., Матвеев А. Н. Эталонная база ВНИИФТРИ в области гидроакустических измерений: метрологические характеристики, функциональные возможности, новации и перспективы совершенствования эталонов. Измерительная техника, 73(12), 46–54 (2024). https://doi.org/10.32446/0368-1025it.2024-12-46-54 ; https://elibrary.ru/dkwbov</mixed-citation><mixed-citation xml:lang="en">Isaev A. E., Kuznetsov S. I., Lomovatskiy Y. A. et al. VNIIFTRI reference base in the field of underwater acoustic measurements: metrological characteristics, functional capabilities, innovations, and prospects for improving standards. Izmeritel`naya Tekhnika, 73(12), 46–54 (2024). (In Russ.) https://doi.org/10.32446/0368-1025it.2024-12-46-54 ; https://elibrary.ru/dkwbov</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Будем ли мы поверять высокотехнологичное медицинское оборудование? Альманах современной метрологии, (9), 153–173 (2017). https://elibrary.ru/ykjuct</mixed-citation><mixed-citation xml:lang="en">Enyakov A. M. Will we calibrate high technology medical equipment? Al’manac of Modern Metrology, (9), 153–173 (2017). (In Russ.) https://elibrary.ru/ykjuct</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Haar G. Ultrasonic imaging: safety considerations. Interface Focus, 1(4), 686–697 (2011). https://doi.org/10.1098/rsfs.2011.0029</mixed-citation><mixed-citation xml:lang="en">Haar G. Ultrasonic imaging: safety considerations. Interface Focus, 1(4), 686–697 (2011). https://doi.org/10.1098/rsfs.2011.0029</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Miller D. L., Smith N. B., Bailey M. R. et al. Overview of therapeutic ultrasound applications and safety considerations. Journal of Ultrasound in Medicine, 31(4), 623–634 (2012). https://doi.org/10.7863/jum.2012.31.4.623 ; https://elibrary.ru/rhzpwd</mixed-citation><mixed-citation xml:lang="en">Miller D. L., Smith N. B., Bailey M. R. et al. Overview of therapeutic ultrasound applications and safety considerations. Journal of Ultrasound in Medicine, 31(4), 623–634 (2012). https://doi.org/10.7863/jum.2012.31.4.623 ; https://elibrary.ru/rhzpwd</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М., Кузнецов С. И., Лукин Г. С. Государственный первичный эталон единицы мощности ультразвука в воде ГЭТ 169-2019. Измерительная техника, (3), 3–8 (2020). https://doi.org/10.32446/0368-1025it.2020-3-3-8 ; https://elibrary.ru/uskvzi</mixed-citation><mixed-citation xml:lang="en">Еnyakov А. М., Kuznetsov S. I., Lukin G. S. State primary measurement standard of ultrasound power unit in water GET 169-2019. Izmeritel`naya Tekhnika, (3), 3–8 (2020). (In Russ.) https://doi.org/10.32446/0368-1025it.2020-3-3-8 ; https://elibrary.ru/uskvzi</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М., Лукин Г. С., Кузнецов С. И. Экспериментальная оценка источников неопределённости измерений полной мощности ультразвукового пучка в воде методом плоского сканирования поперечного сечения пучка. Измерительная техника, (11), 56–61 (2019). https://doi.org/10.32446/0368-1025it.2019-11-56-61 ; https://elibrary.ru/weziep</mixed-citation><mixed-citation xml:lang="en">Еnyakov А. М., Kuznetsov S. I., Lukin G. S. Experimental estimation of the sources of measurement uncertainty of the total power of an ultrasound beam in water by the method of plane scanning of the beam cross section. Izmeritel`naya Tekhnika, (11), 56–61 (2019). (In Russ.) https://doi.org/10.32446/0368-1025it.2019-11-56-61 ; https://elibrary.ru/weziep</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М. Государственный специальный эталон единицы мощности ультразвука в воде. Измерительная техника, (3), 3–7 (2006). https://elibrary.ru/muzjtt</mixed-citation><mixed-citation xml:lang="en">Enyakov А. М. National standard for a unit of ultrasonic power in water. Izmeritel`naya Tekhnika, (3), 3–7 (2006). (In Russ.) https://elibrary.ru/muzjtt</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Кузнецов С. И. Эталонный измеритель мощности ультразвука в воде ЭИМУ-3. Альманах современной метрологии, (3(31)), 31–44 (2022). https://elibrary.ru/nhawan</mixed-citation><mixed-citation xml:lang="en">Kuznetsov S. I. Reference power meter for ultrasound beam in water EIMU-3. Al’manac of Modern Metrology, (3(31)), 31–44 (2022). (In Russ.) https://elibrary.ru/nhawan</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М., Лукин Г. С. Метрологические проблемы измерения мощности ультразвука сфокусированных излучателей высокой интенсивности. Законодательная и прикладная метрология, (1(152)), 47–53 (2018). https://elibrary.ru/unzgvt</mixed-citation><mixed-citation xml:lang="en">Еnyakov А. М., Lukin G. S. Metrological problems of measuring the ultrasonic power of high-intensity focused emissions. Legal and Applied Metrology, (1(152)), 47–53 (2018). (In Russ.) https://elibrary.ru/unzgvt</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Еняков А. М., Кузнецов С. И. Особенности применения звукопрозрачных металлизированных пленок для калибровки гидрофонов методами оптической интерферометрии в свободном поле. Альманах современной метрологии, (3(27)), 85–103 (2021). https://elibrary.ru/hnslfs</mixed-citation><mixed-citation xml:lang="en">Еnyakov А. М., Kuznetsov S. I. Applications of Sound-Transparent Metallized Films for Hydrophone Calibration Using Free-Field Optical Interferometry. Al’manac of Modern Metrology, (3(27)), 85–103 (2021). (In Russ.) https://elibrary.ru/hnslfs</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Лукин, Г. С. Подготовка воды для ультразвуковых измерений. За нами будущее: тезисы докладов III Международной научно-практической конференции молодых ученых и специалистов и тексты работ участников пилотного Международного конкурса «Лучший молодой метролог МГС СНГ», Санкт-Петербург, 11–14 июня 2024 г., с. 355–356 (2024). https://elibrary.ru/gomhrs</mixed-citation><mixed-citation xml:lang="en">Lukin G. S. Preparation of water for ultrasonic measurements. The future is ours: abstracts of reports of the III International scientific and practical conference of young scientists and specialists and texts of works of participants of the pilot international competition “Best young metrologist of the CIS IGS 2024”, St. Petersburg, June 11–14, 2024, pp. 355–356 (2024). (In Russ.) https://elibrary.ru/gomhrs</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
