<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">izmertech-126</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МЕДИЦИНСКИЕ И БИОЛОГИЧЕСКИЕ ИЗМЕРЕНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>MEDICAL AND BIOLOGICAL MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>РАЗРАБОТКА В СРЕДЕ LABVIEW ВИРТУАЛЬНОГО ПРИБОРА ДЛЯ НЕИНВАЗИВНОГО ИЗМЕРЕНИЯ АРТЕРИАЛЬНОГО ДАВЛЕНИЯ</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тычков</surname><given-names>А. Ю.</given-names></name></name-alternatives><email xlink:type="simple">tychkov-a@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Абросимова</surname><given-names>О. В.</given-names></name></name-alternatives><email xlink:type="simple">flickerlight@inbox.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кузьмин</surname><given-names>А. В.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Пензенский государственный университет</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2015</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>9</issue><fpage>68</fpage><lpage>70</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/126">https://www.izmt.ru/jour/article/view/126</self-uri><abstract><p>Рассмотрено виртуальное устройство, имитирующее работу неинвазивного измерителя артериального давления. Использованы новые методики обработки сигнала пульсовой волны и средства взаимодействия с пользователем. Обеспечена возможность загрузки сигналов любого вида, записанных с помощью специального устройства.</p></abstract><trans-abstract xml:lang="en"><p>The virtual device imitating the operation of non-invasive arterial pressure measuring instrument is developed on the base of LabView envirоnment. The advantages of the proposed solution are the new pulse wave signal processing algorithms, means of interaction with users and the loading capabilities for different types of signals registered by means of a special device.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>артериальное давление</kwd><kwd>виртуальный прибор</kwd><kwd>обработка сигналов</kwd><kwd>среда LabView</kwd><kwd>blood pressure</kwd><kwd>virtual insytument</kwd><kwd>signal processing</kwd><kwd>LabView envirenment</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Тычков А. Ю. Перспективы создания персональных медицинских приборов // Биотехнические, медицинские и экологические системы и комплексы: Сб. статей Всерос. науч.-техн. конф. молодых ученых и специалистов «Биомедсистемы-2007». Рязань: РГРТУ, 2007. С. 18-19.</mixed-citation><mixed-citation xml:lang="en">Тычков А. Ю. Перспективы создания персональных медицинских приборов // Биотехнические, медицинские и экологические системы и комплексы: Сб. статей Всерос. науч.-техн. конф. молодых ученых и специалистов «Биомедсистемы-2007». Рязань: РГРТУ, 2007. С. 18-19.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Mitrokhina N. Yu., Kuzmin A. V., Petrunina E. V. Analysis of electrical activity of the heart with the use of geometrical parameters // Biomed. Eng. 2014. V. 47. N. 6. P. 319-322.</mixed-citation><mixed-citation xml:lang="en">Mitrokhina N. Yu., Kuzmin A. V., Petrunina E. V. Analysis of electrical activity of the heart with the use of geometrical parameters // Biomed. Eng. 2014. V. 47. N. 6. P. 319-322.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Бодин О. Н., Чураков П. П., Тычков А. Ю., Кузьмин А. В., Давыдова А. А. Информационно-измерительная система для предварительной обработки флюорографических снимков // Измерительная техника. 2011. № 4. С. 41-44.</mixed-citation><mixed-citation xml:lang="en">Бодин О. Н., Чураков П. П., Тычков А. Ю., Кузьмин А. В., Давыдова А. А. Информационно-измерительная система для предварительной обработки флюорографических снимков // Измерительная техника. 2011. № 4. С. 41-44.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Суранов А. Я. LabVIEW 7: Справочник по функциям. М.: ДМК Пресс, 2005.</mixed-citation><mixed-citation xml:lang="en">Суранов А. Я. LabVIEW 7: Справочник по функциям. М.: ДМК Пресс, 2005.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">National Instruments. LabView: Руководство пользователя. [Электрон. ресурс] http://sine.ni.com/ind-app/app/ind/p/id/ind-3/lang/ru/ (дата обращения 09.12.2014 г.)</mixed-citation><mixed-citation xml:lang="en">National Instruments. LabView: Руководство пользователя. [Электрон. ресурс] http://sine.ni.com/ind-app/app/ind/p/id/ind-3/lang/ru/ (дата обращения 09.12.2014 г.)</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Сойко А. И., Гогин В. А., Клюшкин И. В., Каратаев Р. Н. Поверка современных аппаратов измерения артериального давления и частоты пульса // Казанский медицинский журнал. 2006. Т. 87. № 4. С. 316-317.</mixed-citation><mixed-citation xml:lang="en">Сойко А. И., Гогин В. А., Клюшкин И. В., Каратаев Р. Н. Поверка современных аппаратов измерения артериального давления и частоты пульса // Казанский медицинский журнал. 2006. Т. 87. № 4. С. 316-317.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">National Instruments. Медицина и биотехнологии. [Электрон. ресурс] http://sine.ni.com/ind-app/app/ind/p/id/ind-3/lang/ru/ (дата обращения 09.12.2014 г.)</mixed-citation><mixed-citation xml:lang="en">National Instruments. Медицина и биотехнологии. [Электрон. ресурс] http://sine.ni.com/ind-app/app/ind/p/id/ind-3/lang/ru/ (дата обращения 09.12.2014 г.)</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Национальный Открытый Университет. Активные акустические сенсоры: тонометры, эхолоты, гидролокаторы [Электрон. ресурс] http://www.intuit.ru/studies/courses/590/446/lecture/5586/ (дата обращения 28.12.2014).</mixed-citation><mixed-citation xml:lang="en">Национальный Открытый Университет. Активные акустические сенсоры: тонометры, эхолоты, гидролокаторы [Электрон. ресурс] http://www.intuit.ru/studies/courses/590/446/lecture/5586/ (дата обращения 28.12.2014).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Абросимова О. В., Тычков А. Ю., Кузьмин А. В. Разработка устройства регистрации артериального давления // Перспективные информационные технологии (ПИТ 2014): Труды Междунар. науч-техн. конф.: Самара: Изд-во Самарского научного центра РАН. 2014. C. 256-258.</mixed-citation><mixed-citation xml:lang="en">Абросимова О. В., Тычков А. Ю., Кузьмин А. В. Разработка устройства регистрации артериального давления // Перспективные информационные технологии (ПИТ 2014): Труды Междунар. науч-техн. конф.: Самара: Изд-во Самарского научного центра РАН. 2014. C. 256-258.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
