<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">izmertech</journal-id><journal-title-group><journal-title xml:lang="ru">Измерительная техника</journal-title><trans-title-group xml:lang="en"><trans-title>Izmeritel`naya Tekhnika</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0368-1025</issn><issn pub-type="epub">2949-5237</issn><publisher><publisher-name>ФГУП "ВНИИФТРИ"</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">izmertech-1039</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ФИЗИКО-ХИМИЧЕСКИЕ ИЗМЕРЕНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>PHYSICOCHEMICAL MEASUREMENTS</subject></subj-group></article-categories><title-group><article-title>Измерение сорбции паров на композитной плёнке на основе латекса и активного угля методом кварцекристаллического микровзвешивания</article-title><trans-title-group xml:lang="en"><trans-title></trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Симонов</surname><given-names>В. Н.</given-names></name></name-alternatives><email xlink:type="simple">simonov.valer@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Фомкин</surname><given-names>А. А.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Власов</surname><given-names>Д. А.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Национальный исследовательский ядерный университет «МИФИ»</institution><country>Russian Federation</country></aff><aff xml:lang="ru" id="aff-2"><institution>Институт физической химии и электрохимии им. А.Н. Фрумкина РАН</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>07</day><month>02</month><year>2023</year></pub-date><volume>0</volume><issue>10</issue><fpage>65</fpage><lpage>68</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; ФГУП "ВНИИФТРИ", 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">ФГУП "ВНИИФТРИ"</copyright-holder><copyright-holder xml:lang="en">ФГУП "ВНИИФТРИ"</copyright-holder><license xlink:href="https://www.izmt.ru/jour/about/submissions#copyrightNotice" xlink:type="simple"><license-p>https://www.izmt.ru/jour/about/submissions#copyrightNotice</license-p></license></permissions><self-uri xlink:href="https://www.izmt.ru/jour/article/view/1039">https://www.izmt.ru/jour/article/view/1039</self-uri><abstract><p>Показано, что резонансная частота кварцевого резонатора, покрытого композитной плёнкой на основе латекса и активного угля, под действием паров ацетона не уменьшается, как обычно в кварцекристаллических микровесах, а увеличивается. Приведены характеристики сенсора паров ацетона, реализованного на этом эффекте.</p></abstract><trans-abstract xml:lang="en"><p>It is shown that as a result of changes in mass and elastic properties of the film based on latex and activated carbon, under the influence of acetone vapor, the resonance frequency of the quartz resonator increases by an order greater than usually in quartz microbalances. It is found that the sensitivity of the same sensors to vapors of water and ethyl alcohol is significantly less than the sensitivity to acetone.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>кварцекристаллическое микровзвешивание</kwd><kwd>активные угли</kwd><kwd>синтетический латекс</kwd><kwd>quartz crystal microbalance (QCM)</kwd><kwd>activated carbons</kwd><kwd>synthetic latex</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Малов В.В. Пьезорезонансные датчики. М.: Энергоатомиздат, 1989.</mixed-citation><mixed-citation xml:lang="en">Малов В.В. Пьезорезонансные датчики. М.: Энергоатомиздат, 1989.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang G., Wu C. Quartz crystal microbalance studies on conformational change of polymer chains at interface. Macromolecular Rapid Communications. 2009. V. 30. No. 4-5. Р. 328-335.</mixed-citation><mixed-citation xml:lang="en">Zhang G., Wu C. Quartz crystal microbalance studies on conformational change of polymer chains at interface. Macromolecular Rapid Communications. 2009. V. 30. No. 4-5. Р. 328-335.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Patel R., Zhou R., Zinszer K., Josse F. Real-time detection of organic compounds in liquid environments using polymer-coated thickness shear mode quartz resonators // Analyt. Chem. 2000. V.72. No. 20. Р. 4888-4898.</mixed-citation><mixed-citation xml:lang="en">Patel R., Zhou R., Zinszer K., Josse F. Real-time detection of organic compounds in liquid environments using polymer-coated thickness shear mode quartz resonators // Analyt. Chem. 2000. V.72. No. 20. Р. 4888-4898.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Voinova M.V., Jonson M., KasemoB. Missing mass’ effect in biosensor’s QCM applications//Biosensors and Bioelectronics. 2002. V. 17. Р. 835-841.</mixed-citation><mixed-citation xml:lang="en">Voinova M.V., Jonson M., KasemoB. Missing mass’ effect in biosensor’s QCM applications//Biosensors and Bioelectronics. 2002. V. 17. Р. 835-841.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Kanazawa K., Nam-Joon Cho. Quartz crystal microbalance as a sensor to characterize macromolecular assembly dynamics // J. Sensors. 2009. V. ?. Р. 1-17.</mixed-citation><mixed-citation xml:lang="en">Kanazawa K., Nam-Joon Cho. Quartz crystal microbalance as a sensor to characterize macromolecular assembly dynamics // J. Sensors. 2009. V. ?. Р. 1-17.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Gamby J., Lazerges M., Girault H.H., Deslouis C., Gabrielli C., Perrot H., Tribollet B. Electroacoustic polymer microchip as an alternative to quartz crystal microbalance for biosensor development // Analyt. Chem. 2008. V. 80. No. 23. Р. 8900-8907.</mixed-citation><mixed-citation xml:lang="en">Gamby J., Lazerges M., Girault H.H., Deslouis C., Gabrielli C., Perrot H., Tribollet B. Electroacoustic polymer microchip as an alternative to quartz crystal microbalance for biosensor development // Analyt. Chem. 2008. V. 80. No. 23. Р. 8900-8907.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">McHalea G., Newton M. I. Surface roughness and interfacial slip boundary condition for quartz crystal microbalances // J. Appl. Phys. 2004. V. 95. No. 1. Р. 373-380.</mixed-citation><mixed-citation xml:lang="en">McHalea G., Newton M. I. Surface roughness and interfacial slip boundary condition for quartz crystal microbalances // J. Appl. Phys. 2004. V. 95. No. 1. Р. 373-380.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Jouko Kankare, Kari Loikas, Mikko Salomäki. Method for measuring the losses and loading of a quartz crystal microbalance // Analyt. Chem. 2006. V. 78. Р. 1875-1882.</mixed-citation><mixed-citation xml:lang="en">Jouko Kankare, Kari Loikas, Mikko Salomäki. Method for measuring the losses and loading of a quartz crystal microbalance // Analyt. Chem. 2006. V. 78. Р. 1875-1882.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Seok-Won Lee, Hinsberg W. D., Kanazawa K.K. Determination of the viscoelastic properties of polymer films using a compensated phase-locked oscillator circuit //Analyt. Chem. 2002. V.74. N. 1.Р.125-131.</mixed-citation><mixed-citation xml:lang="en">Seok-Won Lee, Hinsberg W. D., Kanazawa K.K. Determination of the viscoelastic properties of polymer films using a compensated phase-locked oscillator circuit //Analyt. Chem. 2002. V.74. N. 1.Р.125-131.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Rodahl M., Höök F., Kasemo B. QCM operation in liquids: an explanation of measured variations in frequency and Q factor with liquid conductivity // Analyt. Chem. 1996.V. 68. No. 13. Р. 2219-2227.</mixed-citation><mixed-citation xml:lang="en">Rodahl M., Höök F., Kasemo B. QCM operation in liquids: an explanation of measured variations in frequency and Q factor with liquid conductivity // Analyt. Chem. 1996.V. 68. No. 13. Р. 2219-2227.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Тимофеев Д. П. Кинетика адсорбции. М.: Изд-во АН СССР, 1962.</mixed-citation><mixed-citation xml:lang="en">Тимофеев Д. П. Кинетика адсорбции. М.: Изд-во АН СССР, 1962.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">МЭК 60444-1:1986. Измерение параметров кварцевых резонаторов методом с нулевой фазой вπ-образной схеме. Ч. 1. Основной метод измерения резонансной частоты и сопротивления кварцевых резонаторов методом с нулевой фазой и в π-образной схеме.</mixed-citation><mixed-citation xml:lang="en">МЭК 60444-1:1986. Измерение параметров кварцевых резонаторов методом с нулевой фазой вπ-образной схеме. Ч. 1. Основной метод измерения резонансной частоты и сопротивления кварцевых резонаторов методом с нулевой фазой и в π-образной схеме.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
